EMULEX MODEL 375 SAN STORAGE SWITCH | CHAPTER 3: SWITCH MANAGEMENT |
USER’S GUIDE |
Viewing Port Diagnostics
This page displays diagnostic information pertaining to each port in the switch. Use the information provided on this page to diagnose abnormally high error counts on a particular port.
To view the current diagnostic settings:
Click Advanced Functions > Diagnostics > Port.
The Port Diagnostics page appears.
Figure 3-30: Port Diagnostics page
Statistic | Description | |
|
| |
Port & Health | Color Indicators | |
| • | Green |
| • | Yellow |
| • | Red |
| See “Port Utilization and Health” on page 51 for descriptions of the health | |
| indicators. | |
|
| |
Insertion Count | Number of times this port has been inserted into the network since the | |
| switch was reset or the counters were cleared. | |
|
| |
CRC Errors | Number of CRC errors that are detected in frames passing through this port | |
| since the switch was reset or the counters were cleared. | |
|
| |
Ordered Set Errors | Number of Ordered Sets that are received on this port with an encoding | |
| error since the switch was reset or the counters were cleared. | |
|
| |
Clock Delta | Difference (in parts per million) between the internal switch clock and the | |
| received clock signal on the port. | |
|
| |
State | Current state of this port – either inserted or bypassed | |
|
| |
Beacon Port | Forces both port LEDs to flash on and off continuously. Use this to locate | |
| and take action on a specific port. The flashing overrides normal port | |
| indication until beaconing is turned off; however, port operation continues to | |
| operate normally. | |
|
|
|
EMULEX CORPORATION | 55 |