Emulex 375 manual Port Information, Pre-Insertion Testing, Following settings are available

Page 36

EMULEX MODEL 375 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

Port Information

The following settings are available.

Setting

Description

 

 

Smart Setting Name

Displays the name of the Smart Setting. The Smart Setting name

 

will automatically appear in the text box when selected in the scroll

 

menu.

 

 

Smart Setting Type

The topology among switches for a port. Options include:

 

• Initiator or Target Port – the default setting. Should be used when

 

there are no links between switches.

 

• Tree Cascade – designates the port as a tree cascade port. Use

 

this setting when connecting multiple switches together in a tree

 

cascade configuration. Under most conditions, this setting will

 

result in acceptable performance.

 

• String Cascade 1 through String Cascade 4 – designates the

 

string cascade to which a port is assigned. String cascades

 

maintain fairness when two or more InSpeed-based storage

 

switches are serially cascaded. Switch performance may be lower

 

when compared to a tree cascade configuration.

 

 

Pre-Insertion Testing

The following settings are available.

Setting

Description

 

 

Enable Policies/Smart

This policy is the default operating mode for all ports and

Insertion

determines what the switch looks for prior to allowing a port to insert

 

into a zone. When the policy is enabled, an external device is sent

 

an F7 Initialization notification by the switch until an F7 Initialization

 

notification is received from the device. Once an F7 Initialization

 

notification is received, the port is inserted in the zone.

 

This policy takes precedence over all other policies. When this

 

policy is disabled, no additional policies are operational, and as long

 

as a port transmits a signal of the correct frequency and amplitude,

 

the port will be allowed in the zone.

 

 

Port Test Before Insertion

This policy ensures that a device on a port is a valid, standards-

 

compliant participant before allowing the device to be inserted into a

 

zone. The device must meet all of the FC-AL requirements along

 

with going through a complete change notification cycle. During the

 

change notification cycle, the device becomes the Initialization

 

Master (IM) and goes through the change notification phases. Once

 

the change notification cycle is complete, the device can be

 

inserted. This process ensures that a bad device is not allowed into

 

the zone.

 

 

EMULEX CORPORATION

33

PART NUMBER 00041392-002 REV. B

Image 36
Contents Emulex Model ART N Umber 00041392-002 R EV. B Table of Contents Chapter Introduction OverviewFeatures Inspeed TechnologySwitch Applications Storage Consolidation and Shared Storage Pooling3depicts a sample tape library consolidation configuration Tape Library ConsolidationRich Media Server ClusteringInstallation Preparation To unpack the switchRack Installation Desktop InstallationSwitch Installation To place the switch on a desktopInstalling the Retention Clips optional To install the retention clipTo insert the power cord with the retention clip in place To remove the power cord with the retention clip in placeSwitch Leds Ethernet LEDsEthernet LEDs indicate the network connection status System LEDs Port LEDsPower Supply/Fan Module LED Installing an SFP Attaching a Device to the SwitchRemoving an SFP SFP CompatibilityBooting the Switch and SAN To boot the switch and SANPower SUPPLY/FAN Module Replacement To remove an old power supply/fan moduleTo insert a new power supply/fan module Chapter Switch Management Configuring the Network Interface Getting StartedTo connect through a serial interface Connecting to the Web Manager Command Button Description SubmitWeb Manager Overview To connect to the Web ManagerCommand Button Description Cancel RebootLogin/Logout DocumentationInitial Switch Setup Log in to the SwitchChange the Password To log in to the switchChange the Switch Name To view the current date and time Click Switch Date & TimeTo set the date and time settings To change the switch name Click Switch ConfigurationManaging the Switch Frequent Switch Configuration TasksLogging in to the Switch Configuring the Switch SettingsTo change a switch setting To reset the switchGeneral Switch Settings Switch IdentificationNetwork Location Switch Speed To change the switch speed Click Switch ConfigurationVersion Information Blocking ARBSetting Snmp Traps To configure an Snmp trapConfiguring Date and Time Settings To change the time Click Switch Date & TimeTo synchronize time with the host system Click Host Time Changing the Password Switch Password page appearsOpening a Telnet Session Adjusting the Switch Thresholds Switch Thresholds page appearsTo change switch thresholds or time intervals Configuring the Port Smart Settings To view the Port Smart Settings Click Port Smart SettingsPort Smart Settings page appears Default Smart Settings Creating Custom Smart Settings To assign a Smart Setting to one or more portsTo set all ports to the currently selected Smart Setting To create a custom Smart SettingSmart Setting Assignments To modify a custom Smart SettingTo rename a custom Smart Setting To delete a custom Smart SettingPre-Insertion Testing Following settings are availablePort Information Setting Description Stealth Intelligent Change Change NotificationsManager Change Notification onPort Recovery Diagnostics Setting Description Port ControlBypass on Clock Delta Managing Firmware and Configuration Files Switch Firmware FilesTo load new firmware on the switch To check for new firmwareSwitch Configuration Files Restoring the Factory Default SettingsOne-Step Zoning Color Description Down redUp green Not Active yellowSingle-Switch Zoning Adding Devices to Multiple Zones To add storage devices to multiple zonesMultiple Switch Zoning 16 Ports in Multiple Zones on the One-Step ZoningRecovering a Bad Zone Automatically Alpa ZoningConnecting Ports Through Hard Zoning To set up Hard ZoningCascading Switches String CascadesTree Cascades Automatic Trunking 22 Automatic Trunking exampleLoad Balancing 23 Advanced Functions Automatic TrunkingLoad Indicators To change the load balancing settingsViewing Switch Status Monitoring the SwitchFairness and Prioritization Switch Information Current status is provided for the following itemsPort Utilization and Health Port Color Indication GreenYellow RedTo view the event log Click Switch Event Log Viewing the Event LogEvent Log Messages page appears Last time the event log was polled appears at the topViewing Port Information To view port information Click Port InformationPort Information page appears Viewing Port Utilization Port Utilization page appearsValue Description High AverageViewing Port Diagnostics Port Diagnostics page appearsTo save diagnostic information To reset a port Click Advanced Functions Diagnostics PortManual Port Operation To clear the countersViewing Ordered Sets CRC Error Detection Indication F7 InitializationChange Notification UnknownTroubleshooting Device Connections Troubleshooting Management Connections Port Bypass Conditions and RecoveryDefault Smart Setting Attributes Fibre Channel References Appendixes Switch Specifications Operating ConditionsConnecting to the CLI Logging in and OUTTo connect through a network interface To log in to the CLIUsing the CLI Frequent Switch Configuration TasksCLI Commands Severity Description Level Event Event Message SeverityError during Port Disc Port Ptbi failed due to timeoutLIP Cycle Timeout System config reset to factory defaultArbitrated Loop Physical Addresses Hex DecimalAlpa or Arbitrated Loop Physical AddressArbitration Current Fill WordIndex SFP Part Number 00041392-002 REV. B