CHAPTER 2

INSTALLATION REQUIREMENTS

Before installing the FOT-F3 Fiber Optic Transceiver, all conditions, guidelines, specifications, and requirements included in this chapter and Appendix A must be met to ensure satisfactory performance from the FOT-F3. Failure to follow these guidelines may result in unsatisfactory network performance.

2.1NETWORK DESIGN GUIDELINES

The following design guidelines must be met when connecting devices using the FOT-F3.

2.1.1 Fiber Optic Requirements

The fiber optic link segments should consist of single mode 8/125 - 12/125 m fiber optic cabling. You can also use multimode 62.5/125 m fiber optic cabling, but signal distance will be much shorter (about 2 km).

The link segment must be tested with a fiber optic attenuation test set that is adjusted for a 1300 nm wavelength. This test verifies if the signal loss in a cable is within an acceptable level of 9.0 dB or less for any given single mode fiber optic link.

FOT-F3 USER’S MANUAL

2-1

Image 19
Contents FOT-F3 Fiber Optic Transceiver USER’S Manual Page FOT-F3 USER’S Manual DOC Notice FCC NoticeVcci Notice Industrial Environment Declaration of ConformityContents Testing and Troubleshooting Chapter Introduction Using this ManualOverview of the FOT-F3 ConventionsFOT-F3 ConnectionsDistance and Cable Type Signal Quality Error SQE TestLanview LEDs Lanview LEDsRCV Receive PWR PowerSQE Signal Quality Error Test Function XMT TransmitApplication FOT-F3 Setup, ExampleMmac Your email address Getting HelpRelated Manuals Network Design Guidelines Chapter Installation RequirementsFiber Optic Requirements AUI Cable Requirements Installation RequirementsUnpacking the FOT-F3 Chapter InstallationSetting the SQE Switch Connecting the FOT-F3 to the NetworkConnecting the AUI Cable AUI Connection Connecting the Fiber Optic Cable Installation ST Connectors Surface Mounting the FOT-F3 Cable Strain Relief for Surface Mounted FOT-F3 Cable Support InstallationSurface Mounting the FOT-F3 Cable Strain Relief for Non-Mounted FOT-F3Cable Support Installation Installation Installation CHECK-OUT Chapter Testing and TroubleshootingTesting the Fiber Optic Link Segment Testing and Troubleshooting Installation Checkout Testing the FOT-F3 Fiber Optic TransceiverUsing Lanview Collision CLN LED Lanview LEDs Optical Link OK LNK LEDReceive RCV LED Signal Quality Error SQE Test Function LEDTransmit XMT LED Power PWR LED Testing and Troubleshooting Fiber Optic Interface Appendix a SpecificationsAppendix a Specifications Power Supply AUI ConnectorPhysical SafetyEnvironmental Agency Approvals