CHAPTER 4

TESTING AND TROUBLESHOOTING

This chapter lists procedures to test the FOT-F3 after it is connected to the network. A description of LANVIEW and its function in troubleshooting physical layer network problems is also provided.

4.1INSTALLATION CHECK-OUT

This section contains procedures to test the following

The fiber optic link segment to be attached to the FOT-F3.

The FOT-F3 after it has been installed to ensure that the physical layer of the network is operating properly.

4.1.1 Testing the Fiber Optic Link Segment

Test the segment being attached to the FOT-F3 to verify that the cable meets the fiber budget specifications discussed in Chapter 2. Using a fiber optic power meter set, test your link segment as follows:

1.Attach a fiber optic jumper to the optical power meter. The meter should be set at 1300 nm.

2.Attach a fiber optic jumper to the optical source unit. If the source unit has multiple settings, it should be set at 1300 nm.

3.Using a barrel connector, connect the jumpers together.

FOT-F3 USER’S MANUAL

4-1

Image 33
Contents FOT-F3 Fiber Optic Transceiver USER’S Manual Page FOT-F3 USER’S Manual DOC Notice FCC NoticeVcci Notice Industrial Environment Declaration of ConformityContents Testing and Troubleshooting Chapter Introduction Using this ManualOverview of the FOT-F3 ConventionsFOT-F3 ConnectionsDistance and Cable Type Signal Quality Error SQE TestLanview LEDs Lanview LEDsSQE Signal Quality Error Test Function PWR PowerXMT Transmit RCV ReceiveApplication FOT-F3 Setup, ExampleMmac Your email address Getting HelpRelated Manuals Chapter Installation Requirements Network Design GuidelinesFiber Optic Requirements AUI Cable Requirements Installation RequirementsUnpacking the FOT-F3 Chapter InstallationSetting the SQE Switch Connecting the FOT-F3 to the NetworkConnecting the AUI Cable AUI Connection Connecting the Fiber Optic Cable Installation ST Connectors Surface Mounting the FOT-F3 Cable Strain Relief for Surface Mounted FOT-F3 Cable Support InstallationSurface Mounting the FOT-F3 Cable Strain Relief for Non-Mounted FOT-F3Cable Support Installation Installation Chapter Testing and Troubleshooting Installation CHECK-OUTTesting the Fiber Optic Link Segment Testing and Troubleshooting Installation Checkout Testing the FOT-F3 Fiber Optic TransceiverUsing Lanview Collision CLN LED Lanview LEDs Optical Link OK LNK LEDSignal Quality Error SQE Test Function LED Receive RCV LEDTransmit XMT LED Power PWR LED Testing and Troubleshooting Fiber Optic Interface Appendix a SpecificationsAppendix a Specifications Power Supply AUI ConnectorEnvironmental SafetyAgency Approvals Physical