AUI CONNECTOR

A.2 AUI CONNECTOR

The AUI connector is a male DB15 receptacle with a metal shell for cable shielding. Refer to Figure A-1 for pinout identification.

Pin 8

Logic Ref.

Pin 15

No Connection

Pin 7 No Connection

Pin 14

Logic Ref.

Pin 6 Power Return

Pin 13

Power (+12 Vdc)

Pin 5 Receive +

Pin 12

Receive -

Pin 4

Logic Ref.

Pin 11

Logic Ref.

Pin 3 Transmit +

Pin 10

Transmit -

Pin 2

Collision +

Pin 9

Collision -

Pin 1

Logic Ref.

 

 

 

0461-04

Figure A-1 AUI Connector Pinout Identification

A.3 POWER SUPPLY

Table A-2 provides the specifications of the power supply in the FOT-F3.

Table A-2 Power Supply Specifications

Parameter

Typical

Worst

Value

Case

 

 

 

 

Current:

425 mA

475 mA

 

 

 

Input Voltage:

9.0 V

7.5 - 15.75 V

 

 

 

Reset Time:

500 ms

750 ms

 

 

 

FOT-F3 USER’S MANUAL

A-3

Image 43
Contents FOT-F3 Fiber Optic Transceiver USER’S Manual Page FOT-F3 USER’S Manual DOC Notice FCC NoticeVcci Notice Industrial Environment Declaration of ConformityContents Testing and Troubleshooting Chapter Introduction Using this ManualOverview of the FOT-F3 ConventionsFOT-F3 ConnectionsDistance and Cable Type Signal Quality Error SQE TestLanview LEDs Lanview LEDsRCV Receive PWR PowerSQE Signal Quality Error Test Function XMT TransmitApplication FOT-F3 Setup, ExampleMmac Your email address Getting HelpRelated Manuals Network Design Guidelines Chapter Installation RequirementsFiber Optic Requirements AUI Cable Requirements Installation RequirementsUnpacking the FOT-F3 Chapter InstallationSetting the SQE Switch Connecting the FOT-F3 to the NetworkConnecting the AUI Cable AUI Connection Connecting the Fiber Optic Cable Installation ST Connectors Surface Mounting the FOT-F3 Cable Strain Relief for Surface Mounted FOT-F3 Cable Support InstallationSurface Mounting the FOT-F3 Cable Strain Relief for Non-Mounted FOT-F3Cable Support Installation Installation Installation CHECK-OUT Chapter Testing and TroubleshootingTesting the Fiber Optic Link Segment Testing and Troubleshooting Installation Checkout Testing the FOT-F3 Fiber Optic TransceiverUsing Lanview Collision CLN LED Lanview LEDs Optical Link OK LNK LEDReceive RCV LED Signal Quality Error SQE Test Function LEDTransmit XMT LED Power PWR LED Testing and Troubleshooting Fiber Optic Interface Appendix a SpecificationsAppendix a Specifications Power Supply AUI ConnectorPhysical SafetyEnvironmental Agency Approvals