Cabletron Systems F3 user manual Appendix a Specifications

Page 42

APPENDIX A: SPECIFICATIONS

Table A-1 Fiber Optic Interface Specifications (Continued)

Parameter

Typical

Minimum

 

Maximum

 

 

 

 

 

Receive

-31.0 dBm

-36.0 dBm

 

-30.0 dBm

Sensitivity:

 

 

 

 

 

 

 

 

 

 

Max. Receive

-14.0 dBm

Input Power:

 

 

 

 

 

 

 

 

 

Transmitter Power

 

 

 

 

at 25°C Into

-18.0 dBm

-21.0 dBm

 

-15.0 dBm

8.3/125 m fiber:

 

 

 

 

 

 

 

 

 

Output Power

-0.07 dB/°C

 

Coefficient:

 

 

 

 

 

 

 

 

 

 

Notes:

Transmitter Power decreases as temperatures rise and increases as temperatures fall. Use the Output Power Coefficient to calculate increased or decreased power output for your operating environment. For example, the typical power output at 25°C is -16.4 dBm. For a 4°C temperature increase, multiply the typical coefficient (-0.07 dB) by four and add the result to typical output power: (4° C x -0.07 dB/°C) + -16.4 dBm = -16.7 dBm).

The transmitter power levels and receive sensitivity levels given above are Peak Power Levels after optical overshoot. You must use a Peak Power Meter to correctly compare the values given above to those measured on any particular port.

If you are measuring power levels with an Average Power Meter, add 3 dBm to the measurement to correctly compare those measured values to the values listed above

(i.e., -30.5 dBm peak = -33.5 dBm average).

A-2

FOT-F3 USER’S MANUAL

Image 42
Contents FOT-F3 Fiber Optic Transceiver USER’S Manual Page FOT-F3 USER’S Manual FCC Notice DOC NoticeVcci Notice Declaration of Conformity Industrial EnvironmentContents Testing and Troubleshooting Using this Manual Chapter IntroductionConventions Overview of the FOT-F3Connections FOT-F3Signal Quality Error SQE Test Distance and Cable TypeLanview LEDs Lanview LEDsXMT Transmit PWR PowerSQE Signal Quality Error Test Function RCV ReceiveFOT-F3 Setup, Example ApplicationMmac Getting Help Your email addressRelated Manuals Chapter Installation Requirements Network Design GuidelinesFiber Optic Requirements Installation Requirements AUI Cable RequirementsChapter Installation Unpacking the FOT-F3Connecting the FOT-F3 to the Network Setting the SQE SwitchConnecting the AUI Cable AUI Connection Connecting the Fiber Optic Cable Installation ST Connectors Surface Mounting the FOT-F3 Cable Support Installation Cable Strain Relief for Surface Mounted FOT-F3Cable Strain Relief for Non-Mounted FOT-F3 Surface Mounting the FOT-F3Cable Support Installation Installation Chapter Testing and Troubleshooting Installation CHECK-OUTTesting the Fiber Optic Link Segment Testing and Troubleshooting Testing the FOT-F3 Fiber Optic Transceiver Installation CheckoutUsing Lanview Lanview LEDs Optical Link OK LNK LED Collision CLN LEDSignal Quality Error SQE Test Function LED Receive RCV LEDTransmit XMT LED Power PWR LED Testing and Troubleshooting Appendix a Specifications Fiber Optic InterfaceAppendix a Specifications AUI Connector Power SupplyAgency Approvals SafetyEnvironmental Physical