CHAPTER 4: TESTING AND TROUBLESHOOTING

4.Following the instructions for the test set, test the jumpers to get a reference level. Make a note of this reading.

5.Disconnect the jumpers from the barrel connector.

6.Using the jumper, attach the optical power meter to one end of one strand of the link segment.

7.Using the other jumper, attach the other end of the same strand to the optical source unit.

8.Take note of the reading on the optical power meter. This is your test level.

9.Subtract the reference level found in step 4 from the test level to find your dB loss for the fiber optic link segment, i.e., dB loss = Test Level - Reference Level.

10.Verify that the reading on the receive unit matches the specifications listed in theFiber Optic Interface section of Appendix A.

11.Repeat steps 6 through 10 for the other strand in the link segment. If the fiber optic link segment does not meet the specifications, try cleaning the connection at each end of the cable with a soft, clean, lint-free cloth with alcohol, then repeat the test. If this is unsuccessful, contact Cabletron Systems Technical Support as described in Chapter 1, Getting Help, for additional help.

4-2

FOT-F3 USER’S MANUAL

Image 34
Contents FOT-F3 Fiber Optic Transceiver USER’S Manual Page FOT-F3 USER’S Manual FCC Notice DOC NoticeVcci Notice Declaration of Conformity Industrial EnvironmentContents Testing and Troubleshooting Using this Manual Chapter IntroductionConventions Overview of the FOT-F3Connections FOT-F3Signal Quality Error SQE Test Distance and Cable TypeLanview LEDs Lanview LEDsXMT Transmit PWR PowerSQE Signal Quality Error Test Function RCV ReceiveFOT-F3 Setup, Example ApplicationMmac Getting Help Your email addressRelated Manuals Network Design Guidelines Chapter Installation RequirementsFiber Optic Requirements Installation Requirements AUI Cable RequirementsChapter Installation Unpacking the FOT-F3Connecting the FOT-F3 to the Network Setting the SQE SwitchConnecting the AUI Cable AUI Connection Connecting the Fiber Optic Cable Installation ST Connectors Surface Mounting the FOT-F3 Cable Support Installation Cable Strain Relief for Surface Mounted FOT-F3Cable Strain Relief for Non-Mounted FOT-F3 Surface Mounting the FOT-F3Cable Support Installation Installation Installation CHECK-OUT Chapter Testing and TroubleshootingTesting the Fiber Optic Link Segment Testing and Troubleshooting Testing the FOT-F3 Fiber Optic Transceiver Installation CheckoutUsing Lanview Lanview LEDs Optical Link OK LNK LED Collision CLN LEDReceive RCV LED Signal Quality Error SQE Test Function LEDTransmit XMT LED Power PWR LED Testing and Troubleshooting Appendix a Specifications Fiber Optic InterfaceAppendix a Specifications AUI Connector Power SupplyAgency Approvals SafetyEnvironmental Physical