CABLE SUPPORT INSTALLATION

3.4CABLE SUPPORT INSTALLATION

Relieve the strain from the cables attached to the FOT-F3, whether or not the transceiver is mounted to a surface such as a wall.

Note: Be sure each cable is securely attached to its port and that the slide latch on the AUI connector is secured to the lock posts on the AUI port. See Figure 3-2.

To provide strain relief to cables connected to a surface mounted FOT-F3, proceed to Section 3.4.1. For a FOT-F3 that is not surface mounted, proceed to Section 3.4.2.

3.4.1Cable Strain Relief for Surface Mounted FOT-F3

Refer to Figure 3-4 and proceed as follows to relieve the strain on cables connected to a surface-mounted FOT-F3:

1.Remove the protective paper from one of the cable mounts and attach the mount to the wall three inches from the FOT-F3 fiber optic ports.

2.Repeat step 1, placing the other cable mount four inches from the AUI port.

3.Use the tie wraps to secure each cable to its respective cable mount.

FOT-F3 USER’S MANUAL

3-9

Image 29
Contents FOT-F3 Fiber Optic Transceiver USER’S Manual Page FOT-F3 USER’S Manual DOC Notice FCC NoticeVcci Notice Industrial Environment Declaration of ConformityContents Testing and Troubleshooting Chapter Introduction Using this ManualOverview of the FOT-F3 ConventionsFOT-F3 ConnectionsDistance and Cable Type Signal Quality Error SQE TestLanview LEDs Lanview LEDsSQE Signal Quality Error Test Function PWR PowerXMT Transmit RCV ReceiveApplication FOT-F3 Setup, ExampleMmac Your email address Getting HelpRelated Manuals Fiber Optic Requirements Chapter Installation RequirementsNetwork Design Guidelines AUI Cable Requirements Installation RequirementsUnpacking the FOT-F3 Chapter InstallationSetting the SQE Switch Connecting the FOT-F3 to the NetworkConnecting the AUI Cable AUI Connection Connecting the Fiber Optic Cable Installation ST Connectors Surface Mounting the FOT-F3 Cable Strain Relief for Surface Mounted FOT-F3 Cable Support InstallationSurface Mounting the FOT-F3 Cable Strain Relief for Non-Mounted FOT-F3Cable Support Installation Installation Testing the Fiber Optic Link Segment Chapter Testing and TroubleshootingInstallation CHECK-OUT Testing and Troubleshooting Installation Checkout Testing the FOT-F3 Fiber Optic TransceiverUsing Lanview Collision CLN LED Lanview LEDs Optical Link OK LNK LEDTransmit XMT LED Signal Quality Error SQE Test Function LEDReceive RCV LED Power PWR LED Testing and Troubleshooting Fiber Optic Interface Appendix a SpecificationsAppendix a Specifications Power Supply AUI ConnectorEnvironmental SafetyAgency Approvals Physical