Cabletron Systems F3 user manual Using Lanview

Page 36

CHAPTER 4: TESTING AND TROUBLESHOOTING

2.Using another AUI cable (6), connect the other LAN-MD (7) to another FOT-F3 (5) attached to the same fiber optic link segment as the FOT-F3.

3.Select and run test 6 - SERVER on the LAN-MD connected in step 1. Verify that this test passes.

The status on the LAN-MD should read 000 if SQE is enabled or 001 if SQE is disabled. A PASS TEST STATUS LED should also be lit on the LAN-MD.

This LAN-MD now acts as the SERVER unit and will act as a packet echoer when used with another LAN-MD.

4.Select and run test 4 - NODE on the LAN-MD connected in step 2. Verify that this test passes. At least 100 packets should be sent and received with no errors. The packets will be received and sent back from the SERVER LAN-MD that was left running on the other segment.

When the FOT-F3 has successfully completed this test, the units are ready for normal operation. If any failures are noted, please contact Cabletron Systems Technical Support.

4.2USING LANVIEW

The FOT-F3 Fiber Optic Transceiver uses Cabletron Systems LANVIEW, a built-in visual diagnostic and status monitoring system. LANVIEW LEDs are more effective than a network monitor because a network troubleshooter can quickly scan the LEDs to diagnose network problems and to determine which node or segment is faulty.

4-4

FOT-F3 USER’S MANUAL

Image 36
Contents FOT-F3 Fiber Optic Transceiver USER’S Manual Page FOT-F3 USER’S Manual FCC Notice DOC NoticeVcci Notice Declaration of Conformity Industrial EnvironmentContents Testing and Troubleshooting Using this Manual Chapter IntroductionConventions Overview of the FOT-F3Connections FOT-F3Signal Quality Error SQE Test Distance and Cable TypeLanview LEDs Lanview LEDsPWR Power SQE Signal Quality Error Test FunctionXMT Transmit RCV ReceiveFOT-F3 Setup, Example ApplicationMmac Getting Help Your email addressRelated Manuals Chapter Installation Requirements Network Design GuidelinesFiber Optic Requirements Installation Requirements AUI Cable RequirementsChapter Installation Unpacking the FOT-F3Connecting the FOT-F3 to the Network Setting the SQE SwitchConnecting the AUI Cable AUI Connection Connecting the Fiber Optic Cable Installation ST Connectors Surface Mounting the FOT-F3 Cable Support Installation Cable Strain Relief for Surface Mounted FOT-F3Cable Strain Relief for Non-Mounted FOT-F3 Surface Mounting the FOT-F3Cable Support Installation Installation Chapter Testing and Troubleshooting Installation CHECK-OUTTesting the Fiber Optic Link Segment Testing and Troubleshooting Testing the FOT-F3 Fiber Optic Transceiver Installation CheckoutUsing Lanview Lanview LEDs Optical Link OK LNK LED Collision CLN LEDSignal Quality Error SQE Test Function LED Receive RCV LEDTransmit XMT LED Power PWR LED Testing and Troubleshooting Appendix a Specifications Fiber Optic InterfaceAppendix a Specifications AUI Connector Power SupplySafety EnvironmentalAgency Approvals Physical