Cabletron Systems BRIM-F6 manual Table A-1 FPIM-00 and FPIM-01 Specifications

Page 71

APPENDIX A

FPIM SPECIFICATIONS

This appendix describes the FDDI Port Interface Modules (FPIMs).

A.1 FPIM-00 AND FPIM-01

The FPIM-00 and FPIM-01, shown in Figure A-1, provide a multimode fiber connection. The FPIM-00 uses a MIC style connector and the FPIM-01 uses an SC type connector. The specifications for both devices are listed in Table A-1.

Table A-1 FPIM-00 and FPIM-01 Specifications

 

 

Worst

Worst

Typical

Parameter

Typical Value

Case

Case

Budget

 

 

Budget

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive

-30.5 dBm

-28.0 dBm

NA

NA

Sensitivity

 

 

 

 

 

 

 

 

 

Peak Input

-7.6 dBm

-8.2 dBm

NA

NA

Power

 

 

 

 

 

 

 

 

 

50/125 m fiber

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

 

 

 

 

 

62.5/125 m

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

fiber

 

 

 

 

 

 

 

 

 

100/140 m

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

fiber

 

 

 

 

 

 

 

 

 

Error Rate

Better than 1010

 

 

 

 

 

 

 

 

The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD.

Figure A-1 The FPIM-00 and FPIM-01

HSIM-F6 User’s Guide

A-1

Image 71
Contents HSIM-F6 Page HSIM-F6 User’s Guide DOC Notice Cabletron Software Program License HSIM-F6 User’s Guide Declaration of Conformity HSIM-F6 User’s Guide Contents Viii HSIM-F6 User’s Guide Chapter Introduction Document Conventions Using this ManualYour email address Getting HelpOverview FeaturesSpecifications Cabletron Systems Fddi Technology Guide Related DocumentationUnpacking the Hsim Chapter InstallationPress the Fpim connector into the Hsim pins Installing FPIMsInstalling FPIMs Installing an Hsim in an Interface Module Installing AN HsimInstalling an Hsim HSIM-F6 User’s Guide Installing the HSIM-F6 Installing an Hsim in a Standalone HubHSIM-F6 User’s Guide Chapter Local Management Key Function Local Management Keyboard ConventionsKeyboard Conventions Exiting Local Management Screens Selecting Local Management Menu Screen ItemsNavigating Local Management Screens HSIM-F6 Setup ScreenHSIM-F6 Setup Screen HSIM-F6 Configuration HSIM-F6 Statistics Screen HSIM-F6 Statistics ScreenMIB-II Statistics Screen HSIM-F6 Statistics Screen FieldsMIB-II Interface Statistics Screen Fields HSIM-F6 Fddi Ring Statistics Screen Ring Statistics ScreenHSIM-F6 Fddi Ring Statistics Screen Fields MAC Configuration Primary Out Port a Isolated Both port a and port B are isolated from the ring Master Port Count 11 The Ring Map Configuration Screen Ring MAP Configuration ScreenRing Map Configuration Screen Fields Adjusting the Scroll Number n Ring Map Configuration Screen Commands12 The Ring Map Node Information Screen Node Information ScreenNode Information Screen Fields 13 The HSIM-F6 Configuration Screen HSIM-F6 Configuration ScreenHSIM-F6 Configuration Screen Fields 14 The Fddi Full Duplex Configuration Screen Full Duplex Configuration ScreenFull Duplex Fddi Full Duplex Configuration Screen Fields 3 Configuring the HSIM-F6 for Full Duplex Operation FDDI/ETHERNET Translation Configuration Screen Ethernet Ethernet Snap Fddi Translation Configuration Screen FieldsDefault setting for the Novell Fddi 802.2 field is Ethernet Enabled Setting Frame Translation TypesSetting the Interpret 802.3 Length Field to Enabled Setting the Frame Translation Types to the Default ValuesHSIM-F6 User’s Guide Color Definition HSIM-F6 Transmit and Receive LEDsPort a and Port B LED States and Definitions Color DefinitionA, B, P, S LED Definitions HSIM-F6 LED State DefinitionsHSIM-F6 User’s Guide HSIM-F6 LED State Definitions HSIM-F6 User’s Guide Multimode Receiver Specifications Fiber Optic InterfaceMultimode Specifications Multimode Transmitter SpecificationsSingle Mode Receiver Specifications Single Mode SpecificationsMultimode Receiver Signal Detect Specifications Single Mode Transmitter SpecificationsSingle Mode Receiver Signal Detect Single Mode Receiver Signal Detect SpecificationsUTP Transmitter Specifications Unshielded Twisted Pair UTP SpecificationsUTP Receiver Signal Detect UTP Receiver Signal DetectSTP Transmitter Specifications Shielded Twisted Pair STP Transmitter Specifications10 STP Receiver Signal Detect Specifications STP Receiver Signal DetectMultimode Fiber Optic Cable Length Cable SpecificationsSingle Mode Fiber Optic Cable Length Twisted Pair Cable Length Twisted Pair Pinout ConfigurationHSIM-F6 User’s Guide Worst Typical Parameter Typical Value Case Budget Table A-1 FPIM-00 and FPIM-01 SpecificationsFPIM-00 and FPIM-01 Figure A-2 FPIM-02 and FPIM-04 Pinouts FPIM-02 and FPIM-04Parameter Typical Value Minimum Maximum Table A-2 FPIM-05 and FPIM-07 SpecificationsFPIM-05 and FPIM-07 HSIM-F6 User’s Guide