The FDDI/Ethernet Translation Configuration Screen
3.10.3Setting the Frame Translation Types to the Default Values
To return the frame translations to the default settings, perform the following steps:
1.Use the arrow keys to highlight the DEFAULT command at the bottom of the screen and press ENTER.
2.Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER. The “Saved OK” message appears indicating that the changes have been saved to memory.
3.10.4When to Set the Interpret 802.3 Length for Frames > 64 Bytes Field to [ENABLED]
In most network configurations, the default setting of [DISABLED] is appropriate. Some Ethernet devices, however, add padding to frames that are larger than the Ethernet minimum of 64 bytes. If network problems arise with the
3.10.5Setting the Interpret 802.3 Length Field to [ENABLED]
To enable the Interpret 802.3 length for frames > 64 bytes, perform the following steps:
1.Use the arrow keys to highlight the Interpret 802.3 length for frames > 64 bytes field.
2.Use the SPACE bar to toggle the choices until [ENABLED] displays.
3.Use the arrow keys to highlight the SAVE command located at the bottom of the screen.
4.Press ENTER. The configuration changes are saved to memory.
To disable the Interpret 802.3 length for frames > 64 bytes field, perform the steps above while using the SPACE bar to toggle the options until [DISABLED] displays.
|