X15
X16
X17
= Toggle | 0 = Off | 1 = On | |
= xxx.xx | Hrt = horizontal rate (in kHz) Vrt = vertical rate (in Hz) | ||
= Input video type | 1 | = RGB |
|
| 2 | = SMPTE |
|
| 3 | = YUV HDTV |
|
| 4 = BETA 60 |
| |
| 5 = BETA 50 |
| |
| 6 | = YUV Custom |
X18
= Input phase | 0 – 31 |
COMMAND | ASCII RESPONSE | DESCRIPTION |
Input Select |
|
|
|
|
|
Select program input | 1* X1 ! | Out 1•In X1 •All | Display program input | ||
Select preview input | 2* X1 ! | Out 2•In X1 | •All | Display preview input | |
Select program input | 1* X1 & | Out 1•In | X1 | •Rgb | Display program input |
Select preview input | 2* X1 & | Out 2•In | X1 | •Rgb | Display preview input |
1= RGB and audio (if an audio switcher is cascaded), 2 = RGB only
X1
X1
X1
X1
on the program output1 on the preview output1 on the program output2 on the preview output2
Take |
|
|
Implement effect (switch) | % | Tke |
Memory Preset Save | X2 * X3 , |
|
Save preset | X2 Spr |
X3
Implement the current effect
Save the input currently associated with output X2 to memory preset X3
Memory Preset Recall Recall preset
X2 * X3 .
X2 Rpr
X3 | Recall memory preset |
| with output X2 |
X3
to the input associated
Auto Preset Mode
Enable
Disable
View
(disable when manually recalling memory presets)
1 M/m | Aut1 | Enables the SGS to recall settings previously set |
|
| for the input rate. |
0 M/m | Aut 0 | Disables the SGS to automatically recall settings. |
M/m | Aut X15 | View the current auto preset mode setting. |
Contrast Specific value Increment Decrement View
Brightness Specific value Increment Decrement View
X2 * X4 ^ | X2 Con X4 | |
X2 | +^ | X2 Con X4 |
X2 | X2 Con X4 | |
X2 | ^ | X2 Con X4 |
X2 * X5 Y | X2 Brt X5 | |
X2 | +Y | X2 Brt X5 |
X2 | X2 Brt X5 | |
X2 Y | X2 Brt X5 |
Set output X2 contrast to X4
Increase output X2 contrast by one step Decrease output X2 contrast by one step View output X2 contrast setting
Set output X2 brightness to X5
Increase output X2 brightness by one step Decrease output X2 brightness by one step View output X2 brightness setting
Horizontal Shift |
|
|
|
|
|
Increment | X2 +H | X2 Hph + | Shift output | X2 | image right one step |
Decrement | X2 | X2 Hph – | Shift output | X2 | image left one step |
Vertical shift
Increment Decrement
X2 +/
X2
X2 Vph + | Shift output |
X2 Vph – | Shift output |
X2
X2
image down one step image up one step
SGS 408 Switcher • Serial Communication |