COMMAND | RESPONSE | DESCRIPTION | |
|
|
|
|
Query Software Version |
|
|
|
Request Part Number | Q/q | Ver x.xx | Example response: Ver 1.23 |
|
|
| |
| N/n | ||
Request Information |
|
|
|
Program or preview | X2 I/ X2 i | C X1 •Frz X15 •Mut X15 •Hrt X16 •Vrt X16 | |
General | I/i | Exe X15 •Loc X15 •Dvi X15 | |
Examples: | 1I | C2•Frz 0•Mut 0•Hrt 112.20•Vrt 75.02 | |
|
| Program information: Input channel 2, freeze mode is off, mute |
mode is off, horizontal refresh rate is 112.20 kHz, vertical refresh rate is 75.02 Hz
IExe 0•Loc 1•Dvi 1
General information: Executive mode is off, program lockout is on, DVI connector is installed
Advanced Instructions
The Advanced Instructions use hex commands that are more complex than the Simple Instruction Set.
COMMAND | HEX |
| RESPONSE | |
|
|
|
|
|
Read/Write Entire Memory |
|
|
|
|
Read (upload) | 90 91 | 8 kbytes of data + 1 byte checksum | ||
Write (download) | 90 92 + 8 kbytes of data + 1 byte checksum | Dnl | ||
|
|
|
|
|
Read/Write Memory Block |
|
|
|
|
Read to current memory block | X2 | 90 93 | 16 bytes of data + 1 byte checksum | |
Write to a user preset | X3 | 90 94 + 16 bytes of data + 1 byte checksum | Dnl |
Control Software for Windows
The SGS 408 Control Program, which is used by the SGS 408, is compatible with Windows 95/98/2000, and NT. It provides remote control of various functions including input selection, picture controls, effects, transitions, and output rates.
If an ECP 1000 event control panel is attached to the SGS 408, refer to the
ECP 1000 User’s Manual for information on running the SGS 408 Control
Program.
Installing the software
The program is contained on a set of
By default, the Windows installation creates a C:\SGS408 directory, and it will place two icons (SGS 408 Control Pgm and SGS 408 Help) into a group or folder named “Extron Electronics”.
SGS 408 Switcher • Serial Communication |