This default method of addressing was developed with the assumption that not all host adapter manufacturers have designed the hierarchical addressing methodology into their products yet. Since the bit positions here are also easily modified in non-volatile RAM, this addressing will work with all host adapters that only use one byte of LUN addressing.

Fibre Channel to SCSI Address Mapping

Hosts send commands to the FibreBridge (and attached SCSI devices) by sending FCP_CMND (Fibre Channel Command) Frames to the AL_PA assigned to the FibreBridge during loop initialization. Each FCP_CMND frame contains an 8-byte FCP_LUN field. The first level addressing field of the FCP_LUN provides the three SCSI addressing components required to uniquely address a device. FCP_LUN addressing levels 2 – 4 are ignored.

Address Descriptors

The Bus, Target, and LUN fields are set up using Address Descriptors. The SCSI Architecture Model specification provides a guideline mapping the FCP_LUN first level addressing field into SCSI addressing components. The FibreBridge uses user configurable Address Descriptors to effect this translation.

The FibreBridge contains an Address Descriptor for the Peripheral Device, Virtual Device, and Logical Unit addressing methods. The Addressing Method specified in the FCP_LUN (bits 15-14) selects the appropriate Address Descriptor.

Each Address Descriptor defines the size and location of each of the three SCSI addressing components within the FCP_LUN first level addressing field. One hexadecimal digit is assigned to each of Bus, Target, and LUN, with the left 4 bits indicating the rightmost bit-position of the respective field, and the right 4 bits indicating the width of that field. Address Descriptors therefore are three bytes in length, <bus><lun><target>.

For example, an address descriptor 820344 defines the bus (82), LUN (03), and target (44) components. This bus component is a 2 bit field starting in bit-position 8; the LUN component is a 3 bit field starting in bit-position 0; and the target component is a 4 bit field starting in bit-position 4. Additional addressing examples representing typical configurations are provided below. The translation process masks off any unmapped bits, and as a corollary, not all fields need to be mapped. Fields must be contiguous (e.g. bllttb is not permitted - the bus field may not be split).

FibreBridge Address Descriptors are stored in non-volatile memory. They are field configurable using SCSI WRITE/READ BUFFER commands or through ATTO BridgeTools software.

BridgeTools is the preferred method to set the Address Descriptor fields because of the supplied graphical user interface.

SCSI-3 Command Changes for Hierarchical Addressing Support

The FibreBridge supports a limited set of SCSI commands directly, as described in Commands documentation (see References above). A brief description of addressing-related aspects for commands follows.

SCSI-3 INQUIRY Command

The Inquiry Data returned in the response from the SCSI-3 Inquiry command issued to the FibreBridge includes the HiSupport bit set to 1. This indicates that the FibreBridge supports hierarchical addressing,

ATTO Technology, Inc.

- 41 -

Image 46
Contents Atto Technology, Inc Atto FibreBridge Atto Technology, Inc Atto Fibrebridge Benefits and Features Updating the Firmware Within the Fibrebridge Atto Technology, Inc FibreBridge Product Module Description IntroductionFC Rack System Product Description Fibre Channel Technology ReferencesFibre Channel Switch Support Atto FibreBridge Benefits and FeaturesAtto FibreChain Feature FibreBridge Feature ComparisonPhysical Dimensions Atto FC Rack Enclosure and Power ModulesMounting Cooling Airflow EnvironmentalCooling Fans Internal Power Distribution Power ModuleIEC Power Receptacle and Switch LED IndicatorInstallation and Removal Atto FC Rack System Installation Considerations Power Requirements Atto FibreBridge Product Module IntegrationAtto FibreBridge Power Connector Fibre Channel Ports Scsi PortsFibreChain Ports 2100 model only LED IndicatorsAtto FibreChain Port LEDs 2100R model only Ethernet Port Serial PortFibreBridge 2200R/D FibreBridge2200R/D Front View2200R/D Side view with hole dimensions Power Supply Cooling and AirflowFibre Channel Port ScsiLED Indicators on FibreBridge 2200R/D Cabling a FibreBridge Quick Installation InstructionsScsi Cabling Typical Scsi Cables Scsi TerminationFibre Channel Cabling ConnectorConnector Laser Type Cable LengthGbic Installation Instructions Gbic Module and Gbic Guide SystemMedia Interface Adapters MIA Gbic Removal InstructionsPin # Name MIA DB9 Connector MIA InstallationAccessing the Atto FibreBridge over the RS-232 interface FibreBridge ServicesAtto BridgeTools Graphical Interface Configuration Program Monitoring and Managing the Atto FibreBridgeAccessing the Atto FibreBridge over the Ethernet Port Setting up the IP Address using the RS-232 portAccessing through FTP Atto Technology, Inc Serverless Backup Support What is Serverless Backup?Target Descriptors General Operation of Serverless BackupEnabling Serverless Backup on the FibreBridge Segment DescriptorsUpdating the Firmware Within the FibreBridge Flashing the FibreBridgeAddressing Scsi Devices Identifying the FibreBridgeIdentifying the Scsi Devices Connected to the FibreBridge Default Address Translation Appendix a Fibre Channel to Scsi Address Mapping Addressing Devices Connected to the FibreBridgeFibre Channel World Wide Name WWN Fibre Channel AddressingScsi Address Components Arbitrated Loop Port Address AlpaScsi Architecture Model SAM-2 Logical Unit Addressing BitBit Number Address Address Method Specific Definition Peripheral Device Addressing MethodVirtual Device Addressing Method FibreBridge Default ModeLogical Unit Addressing Method Fibre Channel to Scsi Address Mapping SCSI-3 Command Changes for Hierarchical Addressing SupportSCSI-3 Inquiry Command Address DescriptorsSetting the ID of the FibreBridge What to Expect When Setting Device IDsSCSI-3 Report LUNs Command Addressing Connected Scsi DevicesAtto Technology, Inc Configuration for Consecutive IDs Scsi Device ID Translated LUN as it appears to the HostAtto Technology, Inc Canadian Standards Appendix B Radio and Television InterferenceFCC Standards European StandardsFurther results of FCC Testing Maximum Height = 1.582 4.015 cm Maximum Height = 1.272 3.228 cm Figure C-3 Atto FibreBridge 3200R Connector Layout Appendix D Fibre Channel Resources MIAs Appendix E Fibre Channel AccessoriesField Replacement Units FRU Cables/CopperCables/FibreChain Cables/OpticalCables/SCSI Appendix F How to Contact Atto Technology, Inc