PowerSensitivityAdjustment: This dial is normally set fully counter-clockwise, which enables the UPS to provide maximum protection against waveform distortions in its AC input. When such distortion occurs, the UPS will normally switch to providing sine wave power from its battery reserves for as long as the distortion is present. In areas with poor utility power or where the UPS’s input power comes from a backup generator, chronic waveform distortion could cause the UPS to switch to battery too frequently, draining its battery reserves. You may be able to reduce how often your UPS switches to battery due to mod- erate waveform distortion by experimenting with different settings for this dial. As the dial is turned clockwise, the UPS becomes more tolerant of variations in its input power’s AC waveform. NOTE: The further the dial is adjusted clockwise, the greater the degree of waveform distortion the UPS will allow to pass to con- nected equipment. When experimenting with different settings for this dial, operate connected equipment in a safe test mode so that the effect on the equip- ment of any waveform distortions in the UPS’s output can be evaluated without disrupting critical operations.

Input Breaker: Protect your electrical circuit from overcurrent draw from the UPS load. If these breakers trip, remove some of the load, then reset them by pressing the breaker(s) in.

8

Image 8
Contents SmartPro SLT Intelligent, Line-Interactive UPS SystemsImportant Safety Instructions Battery WarningsUPS Location Warnings UPS Connection WarningsTurn the UPS on Plug the UPS into an outlet on a Dedicated circuitPlug your equipment into the UPS USB and RS-232 Serial Communications Buttons Front Panel Indicator Lights Front Panel Other UPS Features Rear Panel Basic Operation Service StorageCarefully pull the front panel away from the UPS Remove old batteriesConnect new batteries Reassemble UPSManual del propietario Inteligentes e interactivos con la líneaInstrucciones de seguridad importantes Advertencias sobre la ubicación del UPSAdvertencias sobre la conexión del UPS Advertencias sobre la conexión de equiposEncienda el UPS Conecte el UPS en una salida de un circuito dedicadoConecte sus equipos en el UPS Comunicaciones USB y serie RS-232 Conexión de puerto EPOBotones Panel frontal Botón ON/OFF/STANDBY Encendido/Apagado/ReservaOperación básica continúa Luces indicadoras Panel frontalOtras funciones del UPS Panel posterior Operación básica continúa Servicio AlmacenamientoQuite las baterías viejas Conecte las nuevas bateríasManuel du propriétaire Mises en garde Emplacement de lUPS Directives de sécurité importantesMises en garde Connexions de lUPS Mises en garde Connexion déquipementMettre lUPS sous tension Brancher lUPS dans une prise dun Circuit dédiéConnecter votre équipement à lUPS Ports de communication de série USB Et RS-232 Connexion au port EPOBoutons Panneau avant Fonctionnement de base, suite Voyants indicateurs Panneau avantAutres caractéristiques de lUPS panneau arrière Fonctionnement de base, suite Service EntreposageRéassemblez lUPS Enlever les anciennes pilesConnecter de nouvelles piles Page 200607046