SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.

UPS Location Warnings

• Use caution when lifting your UPS. Because of the considerable weight of all rackmount UPS

systems, at least two people should assist in lifting and installing them.

• Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.

• For best performance, the ambient temperature near your UPS should be between 0° C and

Mounting

Mount your equipment in either a 4-post or 2-post rack or rack enclosure (see next page for 2-post mounting). The user must determine the fitness of hardware and procedures before mounting. If hardware and procedures are not suitable for your application, contact the manufacturer of your rack or rack enclosure. The procedures described in this manual are for common rack and rack enclosure types and may not be appropriate for all applications.

4-Post Rack Mounting

40° C (between 32° F and 104° F).

• Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its

vents or fan openings.

UPS Connection Warnings

The UPS contains its own energy source (battery). The output terminals may be live even when the UPS is not connected to an AC supply.

Equipment Connection Warnings

• Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or

1

Loosen the wingnuts

A

on each of the two adjustable

 

 

side supports

B

; adjust the length of the supports to

 

match the depth of your rack; tighten wingnuts. Mount

 

both side supports in the lowest space of your rack on

 

the inside surfaces of the rails with user-supplied #10-

 

32 rack bolts and washers

C

. Note: Both support

 

ledges should face inward. The side supports’ front

 

and back holes are threaded and do not require nuts to

 

secure rack bolts.

2

Attach mounting ears

 

 

to the front mounting holes

D

CC

1

B

B

CC

A

A

failure of a Tripp Lite UPS System could cause failure or significantly alter the performance

of a life-support device.

• Do not connect surge suppressors or extension cords to the output of your UPS. This might

overload the UPS and will void the surge suppressor and UPS warranties.

Battery Warnings

• Batteries can present a risk of electrical shock and burn from high short-circuit current.

Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or

batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the

UPS before performing battery replacement. Use tools with insulated handles. There are no

user-serviceable parts inside the UPS. Battery replacement should be performed only by

authorized service personnel using the same number and type of batteries (sealed Lead-Acid).

The batteries are recyclable. Refer to your local codes for disposal requirements or in the

USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-8-228-8379) or visit

www.rbrc.com for recycling information. Tripp Lite offers a complete line of UPS System

Replacement Battery Cartridges (R.B.C.). Visit Tripp Lite on the Web at www.tripplite.com to

locate the specific replacement battery for your UPS.

• During hot-swap battery replacement, the UPS will not provide backup power in the event of

of your UPS E using the screws provided F . The

ears should face forward.

3Using an assistant if necessary, lift your UPS and slide it onto the mounting shelves (if your model includes the shelves). Attach your UPS to the rack by using the appropriate hardware G through its mounting ears and into the rack rails.

E

D

F

2

 

G

 

3

 

a blackout or other power interruptions.

• Do not operate UPS without batteries.

• When adding external battery packs connect only Tripp Lite-recommended battery packs of

the correct voltage and type. Do not connect or disconnect battery packs when the UPS is

operating on battery power.

2

2-Post Rack (Telecom) Mounting

If you mount 3U UPS models in 2-post racks, they require the addition of a Tripp Lite 2-Post Rackmount Installation Kit (model: 2POSTRMKIT, sold separately). See Installation Kit owner’s manual for installation procedure for 3U UPS models.

Tower Mounting

If you tower mount this UPS, it requires the addition of a Tripp Lite 2U to 9U tower stand (model: 2-9USTAND, sold separately). See owner's manual for installation procedure.

3

Image 2
Contents SmartPro 3U Rackmount 5000VA Intelligent, Line-Interactive UPS SystemsImportant Safety Instructions Turn the UPS on Hardwire WarningsPlug your equipment into the UPS Relay Contact-Closure Connection Buttons Front PanelIndicator Lights Front Panel Other UPS Features Rear PanelService StorageProcedure Sistemas de UPS Inteligentes e Interactivos en LíneaInstrucciones de seguridad importantes Guarde Estas InstruccionesEncienda el UPS Instalación rápida Instalación rápida continúaEnchufe su equipo en el UPS ¡ADVERTENCIAS DE CableadoConexión de puerto EPO Instalación opcional continúaConexión de cierre de contacto por relé Conexión de batería externaOperación básica continúa Otras funciones del UPS Panel posteriorAlmacenamiento Servicio¡ADVERTENCIA ProcedimientoSystémes UPS intelligent, en attente active Directives de sécurité importantes Conserver CES DirectivesPorts de communication de série USB et RS-232 Installation rapide Installation rapide suiteMise EN Garde DE Raccordement Connexion au port EPO Installation en option suiteConnexion du contacteur-disjoncteur Connexion de batterie externeFonctionnement de base suite Autres caractéristiques de lUPS panneau arrièreService EntreposageRemarque sur étiquetage ProcédureMise EN Garde 1111W 35th Street Chicago, IL 60609 USAÀêêóìóëÿòîð äëÿ çàìåíû â âàøåì ÓÏÑ Âàæíûå èíñòðóêöèè ïî òåõíèêå áåçîïàñíîñòèÌîíòàæ Áûñòðàÿ óñòàíîâêà Áûñòðàÿ óñòàíîâêà ïðîäîëæåíèå Äîïîëíèòåëüíûé ìîíòàæÎñíîâíîé ðåæèì ðàáîòû Ïîäñîåäèíåíèå êîíòàêòíî-çàìûêàþùåãî ðåëåÎñíîâíîé ðåæèì ðàáîòû ïðîäîëæåíèå Äðóãèå âîçìîæíîñòè ÓÏÑ Çàäíÿÿ ïàíåëüÕðàíåíèå è îáñëóæèâàíèå ÕðàíåíèåÇàìåíà áàòàðåè Îïèñàíèå ïðîöåäóðû

5000 VA specifications

The Tripp Lite 5000 VA is a high-performance uninterruptible power supply (UPS) designed to provide reliable backup power and advanced features for critical systems. This UPS is ideal for healthcare, data centers, and other business environments that require continuous operation and protection from power disturbances.

One of the key features of the Tripp Lite 5000 VA is its robust power capacity. With a powerful 5000 VA rating, it can support a wide range of devices, from servers and networking equipment to medical devices and telecommunications systems. This capacity ensures that essential systems remain operational during power outages, preventing data loss and maintaining operational continuity.

The Tripp Lite 5000 VA incorporates advanced technologies that enhance its performance and efficiency. The unit features automatic voltage regulation (AVR), which ensures stable output voltage by automatically adjusting for fluctuations in input voltage. This regulation helps protect sensitive equipment from damage caused by over-voltage or under-voltage conditions.

Another significant feature is the pure sine wave output, which is crucial for equipment that requires a consistent and high-quality power supply. The pure sine wave output ensures that connected devices, including active PFC power supplies, operate efficiently and effectively. This capability reduces the risk of malfunctions and extends the lifespan of connected equipment.

The Tripp Lite 5000 VA also has a user-friendly LCD display that provides real-time information about the UPS status, including battery charge level, load percentage, and input/output voltage. This information helps users monitor the health of the UPS and the connected equipment, allowing for proactive maintenance and management.

In terms of connectivity, the Tripp Lite 5000 VA is equipped with multiple outlets, ensuring compatibility with various devices. Additionally, the unit often supports USB and serial connections for easy integration with monitoring and management software, enabling remote management capabilities.

The UPS includes hot-swappable batteries, allowing for battery replacement without downtime. This feature enhances the overall reliability of the system, ensuring that critical operations are not interrupted even during maintenance.

Lastly, the Tripp Lite 5000 VA is designed with safety features such as surge protection, overload protection, and short-circuit protection. These features safeguard both the UPS and connected devices, making it a crucial component in power protection strategy.

Overall, the Tripp Lite 5000 VA is a versatile and highly capable UPS solution that meets the demands of critical applications, ensuring uninterrupted power supply and operational excellence.