1Hardwire the UPS System's input terminals to a utility power source.

DANGER!

HIGH VOLTAGE! RISK OF SERIOUS INJURY OR DEATH! FOR QUALIFIED ELECTRICIANS ONLY! ELECTRICIANS MUST READ WARNINGS BELOW AND IN SAFETY SECTION PRIOR TO INSTALLATION.

Before hardwiring, switch OFF the facility's circuit breaker which is supplying power to the circuit the UPS System will be connected to. Using a screwdriv- er, remove the top of the box A covering the UPS System's input terminals. Pass user-supplied cable through the opening in the box B and attach it to the terminals. After hardwiring is complete, switch ON the facility's circuit breaker which is supplying power to the circuit the UPS System is connected to. Note! after the UPS System is connected to a live utility power

A

B

1

Quick Installation continued

2Plug your equipment into the UPS.*

Plug your equipment into the UPS using the addition- al power cord(s) that came with the UPS.

Note: Additional interconnection cords (C13 to C14) are available from Tripp Lite. Call 773-869-1234 (Part # P004-006).

*Your UPS is designed to support only electronic equipment. You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS's Output Capacity. To find your equipment's VA rat- ings, look on their nameplates. If the equipment is listed in amps, mul- tiply the number of amps by 240 to determine VA. (Example: 1 amp × 240 = 240 VA). If you are unsure if you have overloaded the UPS’s outlets, see “OUTPUT LOAD LEVEL” LED description.

3Turn the UPS ON.

Press and hold the “ON/OFF/STANDBY” button for one second. The alarm will beep once briefly after one second has passed. Release the button.

2

3

source, the UPS (in “Standby” mode) will automatical- ly charge its batteries,* but will not supply power to its outlets until it is turned ON (see Step 3 below).

* The BATTERY CHARGE LED will be the only LED illuminated.

Optional Installation

These connections are optional. Your UPS will function properly without these connections.

1USB and RS-232 Serial Communications

HARDWIRE WARNINGS!

Wiring must be done by a qualified electrician.

When making wiring connections, observe the cable connection regulations appropriate to your area at all times. Be sure to install an easily accessible disconnect switch in your installation wiring so you may cut off the UPS's AC input during fires and other emergencies. Ensure that cables are fitted with cable sleeves and are secured by connector clamps. Tighten connections with a torque of not less than 10 inch-pounds (1.1 NM).

Make sure that your equipment is properly grounded.

Using cables of improper size may damage your equipment and cause fire hazards. Choose appropriate cabling and protection circuits to make wiring connections (Ground conductors must be the same size and type as the power conductors used).

Use the included USB cable (see 1a ) and/or DB9 serial cable (see 1b ) to connect the communication port on your computer to the communication port of your UPS. Install on your computer the Tripp Lite PowerAlert Software appropriate to your computer’s operating system. Consult your PowerAlert manual for more information.

1a

1b

4

5

Image 3
Contents Intelligent, Line-Interactive UPS Systems SmartPro 3U Rackmount 5000VAImportant Safety Instructions Hardwire Warnings Plug your equipment into the UPSTurn the UPS on Buttons Front Panel Relay Contact-Closure ConnectionOther UPS Features Rear Panel Indicator Lights Front PanelStorage ServiceSistemas de UPS Inteligentes e Interactivos en Línea ProcedureGuarde Estas Instrucciones Instrucciones de seguridad importantes¡ADVERTENCIAS DE Cableado Instalación rápida Instalación rápida continúaEnchufe su equipo en el UPS Encienda el UPSConexión de batería externa Instalación opcional continúaConexión de cierre de contacto por relé Conexión de puerto EPOOtras funciones del UPS Panel posterior Operación básica continúaServicio AlmacenamientoProcedimiento Systémes UPS intelligent, en attente active¡ADVERTENCIA Conserver CES Directives Directives de sécurité importantesInstallation rapide Installation rapide suite Mise EN Garde DE RaccordementPorts de communication de série USB et RS-232 Connexion de batterie externe Installation en option suiteConnexion du contacteur-disjoncteur Connexion au port EPOAutres caractéristiques de lUPS panneau arrière Fonctionnement de base suiteEntreposage Service1111W 35th Street Chicago, IL 60609 USA ProcédureMise EN Garde Remarque sur étiquetageÂàæíûå èíñòðóêöèè ïî òåõíèêå áåçîïàñíîñòè ÌîíòàæÀêêóìóëÿòîð äëÿ çàìåíû â âàøåì ÓÏÑ Äîïîëíèòåëüíûé ìîíòàæ Áûñòðàÿ óñòàíîâêà Áûñòðàÿ óñòàíîâêà ïðîäîëæåíèåÏîäñîåäèíåíèå êîíòàêòíî-çàìûêàþùåãî ðåëå Îñíîâíîé ðåæèì ðàáîòûÄðóãèå âîçìîæíîñòè ÓÏÑ Çàäíÿÿ ïàíåëü Îñíîâíîé ðåæèì ðàáîòû ïðîäîëæåíèåÕðàíåíèå Õðàíåíèå è îáñëóæèâàíèåÎïèñàíèå ïðîöåäóðû Çàìåíà áàòàðåè

5000 VA specifications

The Tripp Lite 5000 VA is a high-performance uninterruptible power supply (UPS) designed to provide reliable backup power and advanced features for critical systems. This UPS is ideal for healthcare, data centers, and other business environments that require continuous operation and protection from power disturbances.

One of the key features of the Tripp Lite 5000 VA is its robust power capacity. With a powerful 5000 VA rating, it can support a wide range of devices, from servers and networking equipment to medical devices and telecommunications systems. This capacity ensures that essential systems remain operational during power outages, preventing data loss and maintaining operational continuity.

The Tripp Lite 5000 VA incorporates advanced technologies that enhance its performance and efficiency. The unit features automatic voltage regulation (AVR), which ensures stable output voltage by automatically adjusting for fluctuations in input voltage. This regulation helps protect sensitive equipment from damage caused by over-voltage or under-voltage conditions.

Another significant feature is the pure sine wave output, which is crucial for equipment that requires a consistent and high-quality power supply. The pure sine wave output ensures that connected devices, including active PFC power supplies, operate efficiently and effectively. This capability reduces the risk of malfunctions and extends the lifespan of connected equipment.

The Tripp Lite 5000 VA also has a user-friendly LCD display that provides real-time information about the UPS status, including battery charge level, load percentage, and input/output voltage. This information helps users monitor the health of the UPS and the connected equipment, allowing for proactive maintenance and management.

In terms of connectivity, the Tripp Lite 5000 VA is equipped with multiple outlets, ensuring compatibility with various devices. Additionally, the unit often supports USB and serial connections for easy integration with monitoring and management software, enabling remote management capabilities.

The UPS includes hot-swappable batteries, allowing for battery replacement without downtime. This feature enhances the overall reliability of the system, ensuring that critical operations are not interrupted even during maintenance.

Lastly, the Tripp Lite 5000 VA is designed with safety features such as surge protection, overload protection, and short-circuit protection. These features safeguard both the UPS and connected devices, making it a crucial component in power protection strategy.

Overall, the Tripp Lite 5000 VA is a versatile and highly capable UPS solution that meets the demands of critical applications, ensuring uninterrupted power supply and operational excellence.