Network Technologies DVB-ASI to IP, ASI-IP-GTW user manual AC Mains Input, DC Mains input

Page 82

ASI-IP-GTW User's Manual

Item

Specification

Connector type

9-pin DSUB Male

 

 

RS232 baudrate

115,2 kbaud

 

 

RS232 framing

8 bit, no parity, 1 stop bit

 

 

RS232 handshake

None

 

 

Relay rating

0.1 A max, 50 Vdc max

 

 

Relay minimum load

10 µA at 10 mVdc

 

 

 

Pins

1.

NC

 

2.

RS232 Receive Data (input)

 

3.

RS232 Transmit Data (output)

 

4. NC

 

5.

Ground

 

6.

Alarm on

 

7.

Alarm relay common

 

8.

Alarm off

 

9. NC

 

 

Safety status (UK)

SELV

 

 

 

8.5 AC Mains Input

Table 21. AC Power Supply Specification

Item

Specification

Rated voltage

100-240 VAC

 

 

Voltage tolerance limits

85-264 VAC

 

 

Rated frequency

50/60 Hz

 

 

Rated current

0.7 A

 

 

Power consumption

< 50 W

 

 

8.6 DC Mains input

Table 22. DC Power Supply Specification

Item

Specification

Rated voltage

48 VDC

 

 

Voltage tolerance limits

36-72 VDC

 

 

Power consumption

< 60 W

 

 

Page 82

Image 82
Contents DVB-ASI to IP Gateway This page is intentionally left blank Important notice Rev Date SW ver CommentPage Table of Contents Options 12.1 Purpose of this Manual IntroductionWho Should Use this Manual Contact Information What Equipment is Covered by this ManualRole of the ASI-IP-GTW in a Typical System Summary of FeaturesSoftware versions Page User Interface Indicator Colour DescriptionGuided Tour Front Panel DescriptionConstruction Hardware OptionsSoftware Options Functionality Max value DescriptionInstalling the Equipment Installing the EquipmentIntroduction To cable the equipment Equipment accessTo fix the equipment VentilationTo connect the equipment ASI portAC Power Supply PowerPower Cable and Protective Earth UK BS Protective Earth /Technical EarthUSA Nema 5-15P Connecting the Video Gateway to the AC Power Supply Optional DC Power SupplyPin placement Specification Introduction Signal ConnectionsASI ports DVB ASI input Ethernet data portDVB ASI output LEDs Ethernet management portPowering Up Powering Up/DownBefore Powering up Powering DownOperating the Equipment Changing the IP address of the unitLooking at the WEB interface Overall statusMain tab Sub-tab Description SnmpStatus Device Info Product type ASI-IP-GTWNetwork MainAdvanced 1.22 SFPDevice info page, Network and SFP sub-page Time settings Shows the sub-page for time setting used for alarm reportsAlarms SnmpSnmp tab Ping Ping tabPage Shows the sub-page for user security password protection SecurityIP TX Input ConfigurationMain Input Status IP TX ParametersIP TX Status FEC Settings IP TX FECPage Vlan settings Ethernet SettingsStatic MAC setting Ping Settings Ping page of an IP transmitterOutput Configuration IP RXIP RX Parameters Output StatusIP RX Status FEC sub-page of an IP receiver Page Ethernet sub-page of an IP receiver Ping page of an IP receiver Advanced Tab Advanced TabPage Data Network Interface Status NetworkTransmitted Network streams Shows the Network page for a unit configured to IP-RX mode Received Network streamsSaving a Configuration Save/LoadLoading a Configuration Save/Load page when saving configurationSeparate 10MHz/1PPS module Options1PPS/10MHz interface modules 2 1PPS interfaceOperating the 1PPS/10MHz interface module Shows the layoutLED descriptions LED description for separate 1PPS/10MHz interface moduleRIPv2 functionality Shows the layout of the RIP-2 screenPage Equipment Description IP Transmit ModeFunctional Description IP Bi-directional Mode IP Receive ModeManagement Page Alarm Severity level Description Overview of Video over IP Protocol mappingForward Error Correction FEC Data Flow Block DiagramsUDP Mode Page Preventive Maintenance Preventive Maintenance and Fault-findingMaintenance Fault finding Philosophy Fault-findingPreliminary Checks PSU LED Unlit / Power Supply Problem Step Action If the result of action is Yes Check Fan Alarm LED lit / Alarm conditionFans Not Working / Overheating RotationAlarm Description Error source Progress Bitrate estimationTo return the unit Disposing of this EquipmentGeneral Appendix a Glossary Page Page Page Appendix B Technical Specification DVB ASI portEthernet management port Alarm relay and maintenance port specificationEthernet data port ProtocolsAC Mains Input DC Mains inputPhysical Details Compliance1 SafetyEnvironmental Conditions Electromagnetic Compatibility EMCCE Marking Interface to public telecommunication systemAppendix C References Appendix D Upgrade of Features Ex. http//192.168.0.100/upgradeFeature upgrade Feature upgrade dialogue Upgrade SW Appendix E Upgrading SoftwareSW load progress Mpls Appendix F Quality of service Setting Packet priorityLayer 3 Routing ASI-IP-GTW Configuration Layer 2 priority