Paradyne 3600 Series, 3611, 3610 manual Introduction, Overview

Page 11

Introduction 1

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

Equipment Warranty and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

Overview

The COMSPHERE ± 48 Vdc Central Office (CO) Power Unit is designed to provide low voltage dc power to any data communication equipment (DCE) operating in a COMSPHERE 3000 Series Carrier.

The ± 48 Vdc CO Power Unit (hereafter referred to as the CO Power Unit) consists of the following components:

One CO power tray with mounted backplane

One power module

Two backplane connector cable assemblies

Two air filter brackets

One installation kit which includes the following:

ÐTwo dc input connector housings and six contacts for the customer-supplied dc input cable

ÐFour air filter bracket screws

ÐTwo nylon cable ties

You must supply the following related components:

A second power module, if desired.

One or two ± 48V power input cables. The required number of input cables depends upon your configuration.

One air filter, if needed.

Alarm cables and NMS adapter cable, if needed. These components are used to connect the CO Power Unit to a CO alarm system and/or a COMSPHERE 6800 Series Network Management System (NMS) through a Modular 3611 Data Service Unit (DSU).

(A Modular 3611 DSU has a row of contacts on the rear edge of the circuit card and is shipped with a rear connector plate. The rear connector plate allows the removal of a Modular 3611 DSU from the front of the carrier without first disconnecting the DTE cables at the rear of the carrier. The NMS adapter cable is only compatible with the Modular 3611 DSU. For more information on the Modular 3611 DSU, see the COMSPHERE 3600 Series Data Service Units, Models 3610 and 3611, Operator's Guide.)

The total number of components required depends upon your configuration. The ACCULINK 3151 CSUs and 3161 DSU/CSUs do not support forwarding of CO Power Unit alarms to a 6800 Series NMS.

The CO Power Unit can send alarms to a CO alarm system and a 6800 Series NMS simultaneously. To connect to a CO alarm system, you need one customer-supplied alarm cable for each power module. To forward alarms to a 6800 Series NMS, you need one Modular 3611 DSU (configured to forward alarms to a 6800 Series NMS) and one NMS adapter cable. You can also use a non-modular Model 3611 DSU, but you must build your own cable. This guide provides information on forwarding alarms to a 6800 Series NMS via a Modular 3611 DSU, but reminds you that a non-modular Model 3611 DSU can also be used.

3000-A2-GB41-40

May 1998

1-1

Image 11
Contents Comsphere ±48 Vdc Central Office Power Unit Copyright  1998 Paradyne Corporation. All rights reserved Warranty, Sales, and Service InformationTrademarks Important Safety Instructions Comsphere ±48 Vdc Central Office Power Unit Table of Contents Interface Connections Glossary Index List of Figures List of Tables Technical Specifications for Central Office CO Power UnitRelated Documents PrefaceObjectives and Reader Assumptions AbstractComsphere ±48 Vdc Central Office Power Unit Overview Introduction2illustrates the CO Power Unit with two power modules FeaturesCentral Office CO Power Unit with One Power Module ±48 Vdc Technical SpecificationsWeight Equipment Warranty SupportComsphere ±48 Vdc Central Office Power Unit May Basic Mode of Operation Installation ConsiderationsWithout DBMs DSUs with DBMs DSUs, 3151 and CSUs Independent Mode of OperationAmbient 3611 DSUs 3551, 3611, 3161 DSU/CSUsAlarm Forwarding to a 6800 Series NMS Redundant Mode of OperationProcedure CO Power Unit InstallationInstalling the Optional Second Power Module Installing the Optional Second Power Module Settings for Basic Mode Setting the Option StrapsSettings for Independent Mode Independent ModeSeries Carrier Installation Manual Installing the CO Power UnitCO Power Unit Installation Comsphere 3000 Series Carrier Rear Providing Power to a CO Power UnitAMP Procedure GRD Optional Fuses -48V GRD Vdc Power Source a  Procedure Installing an SdcpConnecting the Alarm Contacts to a CO Alarm System Ext Leads RPowr Procedure Installation Air Filter and Brackets Installation Optional 11. Air Filter Brackets Installation Comsphere ±48 Vdc Central Office Power Unit May Indicators and Controls Troubleshooting and MaintenanceTroubleshooting Replacing a Power Module Power Module Replacement InstructionsPreventive Maintenance DC Inputs Interface Connections a±48V CO ground return Figure A-2. Connector Housing and Contact Pin Assignments for CO Alarm System OutputsCO Alarm System Outputs Table A-3NMS Alarm Outputs Figure A-3. NMS Adapter Cable Feature Number 3000-F2-510 Glossary Basic modeSDU Index NMS Index