Paradyne 3610, 3611, 3600 Series manual Troubleshooting

Page 40

COMSPHERE ±48 Vdc Central Office Power Unit

Troubleshooting

If operating in the Basic mode and the power module's Power LED is red, check the DCEs in the carrier. If the LEDs on the DCEs are not lit, try resetting the power module. (Reset the power module by removing the power module and then reinstalling it.) If the Power LED remains red after resetting the power module, you should replace the power module. Do not remove the failed power module until a replacement power module is available. If the power LED is red and the DCEs appear to be working, schedule maintenance for the power module after peak hours at which time you can try resetting the power power module and/or replacing it. If the Fan Alarm LED is yellow and the DCEs in the carrier appear to be working, you may want to schedule maintenance after peak hours.

If operating in the Independent mode and one of the power module's Power LED is red, check the DCEs in the carrier.

If the LEDs on the DCEs above the power modules are not lit, try resetting the power module. (Reset the power module by removing the power module and then reinstalling it.) If the Power LED remains red after resetting the power module, you should replace the power module. Do not remove the failed power module until a replacement power module is available.

If the DCEs appear to be working, schedule maintenance for the power module after peak hours at which time you can try resetting the power module and/or replacing it.

Also in Independent mode, if the Fan Alarm LED is yellow and the DCEs in the carrier appear to be working, you may want to schedule maintenance after peak hours.

If operating in the Redundant mode and one of the power module's Power LED is red, try resetting the power module by removing the power module and then reinstalling it. If the Power LED remains red, you should replace the power module.

In addition, if the Fan Alarm LED is yellow, try resetting the power module. If the Fan Alarm LED remains yellow, you should replace the power module.

In all modes of operation, if the Power LED is not lit, check the input power source and external fuses before replacing the power module. If ± 48V is present at the input connector, replace the power module. If ± 48V is not present, check your distribution system.

3-2

May 1998

3000-A2-GB41-40

Image 40
Contents Comsphere ±48 Vdc Central Office Power Unit Trademarks Warranty, Sales, and Service InformationCopyright  1998 Paradyne Corporation. All rights reserved Important Safety Instructions Comsphere ±48 Vdc Central Office Power Unit Table of Contents Interface Connections Glossary Index List of Figures Technical Specifications for Central Office CO Power Unit List of TablesPreface Objectives and Reader AssumptionsAbstract Related DocumentsComsphere ±48 Vdc Central Office Power Unit Introduction OverviewFeatures 2illustrates the CO Power Unit with two power modulesCentral Office CO Power Unit with One Power Module Technical Specifications ±48 VdcEquipment Warranty Support WeightComsphere ±48 Vdc Central Office Power Unit May Installation Considerations Basic Mode of OperationIndependent Mode of Operation Ambient 3611 DSUs 3551, 3611,3161 DSU/CSUs Without DBMs DSUs with DBMs DSUs, 3151 and CSUsRedundant Mode of Operation Alarm Forwarding to a 6800 Series NMSInstalling the Optional Second Power Module CO Power Unit InstallationProcedure Installing the Optional Second Power Module Setting the Option Straps Settings for Basic ModeIndependent Mode Settings for Independent ModeInstalling the CO Power Unit Series Carrier Installation ManualCO Power Unit Installation Providing Power to a CO Power Unit Comsphere 3000 Series Carrier RearAMP Procedure GRD Optional Fuses -48V GRD Vdc Power Source a Installing an Sdcp  ProcedureConnecting the Alarm Contacts to a CO Alarm System Ext Leads RPowr Procedure Installation Air Filter and Brackets Installation Optional 11. Air Filter Brackets Installation Comsphere ±48 Vdc Central Office Power Unit May Troubleshooting and Maintenance Indicators and ControlsTroubleshooting Power Module Replacement Instructions Replacing a Power ModulePreventive Maintenance Interface Connections a DC Inputs±48V CO ground return Figure A-2. Connector Housing and Contact CO Alarm System Outputs CO Alarm System OutputsTable A-3 Pin Assignments forNMS Alarm Outputs Figure A-3. NMS Adapter Cable Feature Number 3000-F2-510 Basic mode GlossarySDU Index NMS Index