COMSPHERE ±48 Vdc Central Office Power Unit

To connect the alarm contacts to the external leads of a Modular 3611 DSU (configured for alarm forwarding):

"Procedure

1.At the rear of the carrier, plug the 6-wire modular plug end of the NMS adapter cable into the J1 connector (a 6-position modular jack) on the CO Power Unit's backplane (see Figure 2-9).

2.If there is an EIA-232 cable on the top connector (labeled EIA232/V.24) of a Modular 3611 DSU's

rear connector plate, remove the ferrite choke and the EIA-232 cable. Plug the DB25 male end of the NMS adapter cable into the top connector of the rear connector plate. Tighten the screws to hold the cable in place. Then, attach the ferrite choke to the NMS adapter cable. Plug the EIA-232 cable into the DB25 female end of the NMS adapter cable. Tighten the screws to hold the cable in place. See Figure 2-9.

Figure 2-9. Connecting an NMS Adapter Cable to a Modular 3611 DSU

When the DTE Interface is EIA-232

2-18

May 1998

3000-A2-GB41-40

Image 34
Contents Comsphere ±48 Vdc Central Office Power Unit Trademarks Warranty, Sales, and Service InformationCopyright  1998 Paradyne Corporation. All rights reserved Important Safety Instructions Comsphere ±48 Vdc Central Office Power Unit Table of Contents Interface Connections Glossary Index List of Figures Technical Specifications for Central Office CO Power Unit List of TablesAbstract PrefaceObjectives and Reader Assumptions Related DocumentsComsphere ±48 Vdc Central Office Power Unit Introduction OverviewFeatures 2illustrates the CO Power Unit with two power modulesCentral Office CO Power Unit with One Power Module Technical Specifications ±48 VdcEquipment Warranty Support WeightComsphere ±48 Vdc Central Office Power Unit May Installation Considerations Basic Mode of Operation3161 DSU/CSUs Independent Mode of OperationAmbient 3611 DSUs 3551, 3611, Without DBMs DSUs with DBMs DSUs, 3151 and CSUsRedundant Mode of Operation Alarm Forwarding to a 6800 Series NMSInstalling the Optional Second Power Module CO Power Unit InstallationProcedure Installing the Optional Second Power Module Setting the Option Straps Settings for Basic ModeIndependent Mode Settings for Independent ModeInstalling the CO Power Unit Series Carrier Installation ManualCO Power Unit Installation Providing Power to a CO Power Unit Comsphere 3000 Series Carrier RearAMP Procedure GRD Optional Fuses -48V GRD Vdc Power Source a Installing an Sdcp  ProcedureConnecting the Alarm Contacts to a CO Alarm System Ext Leads RPowr Procedure Installation Air Filter and Brackets Installation Optional 11. Air Filter Brackets Installation Comsphere ±48 Vdc Central Office Power Unit May Troubleshooting and Maintenance Indicators and ControlsTroubleshooting Power Module Replacement Instructions Replacing a Power ModulePreventive Maintenance Interface Connections a DC Inputs±48V CO ground return Figure A-2. Connector Housing and Contact Table A-3 CO Alarm System OutputsCO Alarm System Outputs Pin Assignments forNMS Alarm Outputs Figure A-3. NMS Adapter Cable Feature Number 3000-F2-510 Basic mode GlossarySDU Index NMS Index