Paradyne 3611, 3610, 3600 Series manual Troubleshooting and Maintenance, Indicators and Controls

Page 39

Troubleshooting and Maintenance 3

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

Indicators and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

Power Module Replacement Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

Overview

This chapter describes the status indicators on the power module's faceplate, provides troubleshooting guidelines and replacement instructions for the power module, and a preventive maintenance schedule for the optional air filter.

Indicators and Controls

The CO Power Unit detects power module and/or fan failures by monitoring the power output levels and the fan's low-speed sensor for proper operation of the power module. When a failure occurs, an alarm indication light appears on the faceplate of the affected power module.

There are two LED status indicators (Figure 3-1) on the power module's faceplate: the Power LED and the Fan Alarm LED. The Power LED provides the status of the power module. A green light indicates that the power module is operating properly. A red light indicates a power module failure. No light indicates that the CO Power Unit is not receiving input power. The Fan Alarm LED provides the status of the fan in the power module. If the Fan Alarm LED is not lit and the Power LED is green, the fan is operating properly. If the LED is yellow, it indicates either a fan failure or a fan speed below

1900 rpm.

 

Power

3000 DC Power Module

Fan Alarm

491-13698

Figure 3-1. LED Status Indicators

3000-A2-GB41-40

May 1998

3-1

Image 39
Contents Comsphere ±48 Vdc Central Office Power Unit Warranty, Sales, and Service Information TrademarksCopyright  1998 Paradyne Corporation. All rights reserved Important Safety Instructions Comsphere ±48 Vdc Central Office Power Unit Table of Contents Interface Connections Glossary Index List of Figures List of Tables Technical Specifications for Central Office CO Power UnitRelated Documents PrefaceObjectives and Reader Assumptions AbstractComsphere ±48 Vdc Central Office Power Unit Overview Introduction2illustrates the CO Power Unit with two power modules FeaturesCentral Office CO Power Unit with One Power Module ±48 Vdc Technical SpecificationsWeight Equipment Warranty SupportComsphere ±48 Vdc Central Office Power Unit May Basic Mode of Operation Installation ConsiderationsWithout DBMs DSUs with DBMs DSUs, 3151 and CSUs Independent Mode of OperationAmbient 3611 DSUs 3551, 3611, 3161 DSU/CSUsAlarm Forwarding to a 6800 Series NMS Redundant Mode of OperationCO Power Unit Installation Installing the Optional Second Power ModuleProcedure Installing the Optional Second Power Module Settings for Basic Mode Setting the Option StrapsSettings for Independent Mode Independent ModeSeries Carrier Installation Manual Installing the CO Power UnitCO Power Unit Installation Comsphere 3000 Series Carrier Rear Providing Power to a CO Power UnitAMP Procedure GRD Optional Fuses -48V GRD Vdc Power Source a  Procedure Installing an SdcpConnecting the Alarm Contacts to a CO Alarm System Ext Leads RPowr Procedure Installation Air Filter and Brackets Installation Optional 11. Air Filter Brackets Installation Comsphere ±48 Vdc Central Office Power Unit May Indicators and Controls Troubleshooting and MaintenanceTroubleshooting Replacing a Power Module Power Module Replacement InstructionsPreventive Maintenance DC Inputs Interface Connections a±48V CO ground return Figure A-2. Connector Housing and Contact Pin Assignments for CO Alarm System OutputsCO Alarm System Outputs Table A-3NMS Alarm Outputs Figure A-3. NMS Adapter Cable Feature Number 3000-F2-510 Glossary Basic modeSDU Index NMS Index