1 General Information

The Quatech, Inc. DSCLP-200/300 (two-port) and SSCLP-200/300 (one-port) provide RS-422 or RS-485 asynchronous serial communication interfaces for IBM-compatible personal computer systems using the PCI expansion bus. For general purposes, this manual usually makes reference only to the DSCLP-200/300. All information pertains equally to the SSCLP-200/300, with the exception that with the SSCLP there is just one port instead of two. The DSCLP-200/300 uses Quatech's new Enhanced Serial Adapter design. Legacy serial port data rates are limited to a maximum of 115,200 bits per second. Quatech Enhanced Serial Adapters can achieve data rates as high as 921,600 bits per second.

As a PCI device, the DSCLP-200/300 requires no hardware configuration. The card is automatically configured by the computer's BIOS or operating system. The two serial ports share a single interrupt line and are addressed in a contiguous block of 16 bytes. A special interrupt status register is provided to help software to manage the shared interrupt.

The DSCLP-200/300's serial ports are implemented using 16550 Universal Asynchronous Receiver/Transmitters (UARTs). These UARTs contain hardware buffers (FIFOs) which reduce processing overhead and allow higher data rates to be achieved. The 16550 contains a 16-byte FIFO and can transmit and receive data at a rate of up to 921,000 bits per second.

The DSCLP-200/300 is supported under several popular operating systems and environments. Contact the sales department for details on current software offerings. Most device drivers are available for download from the Quatech world wide web site at http://www.quatech.com.

DSCLP/SSCLP-200/300 User's Manual

8

Image 8
Contents DSCLP/SSCLP-200/300 Warranty Information Iii Manufacturers Name Manufacturers AddressApplication of Council Directive Standards to which Conformity is DeclaredHardware Configuration Hardware Installation Address Map and Special RegistersRS-422 or RS-485 Signal Line Termination Base Address and Interrupt Level IRQHalf-Duplex/Full-Duplex/Auto-Toggle Selection Page General Information Jumpers J6-J9 Signal Connections Full-duplex/Half-duplex OperationJumpers J10-J23 define the options for this card Right Card Edge Jumpers1 CTS0SEL, CTS1SEL J10 Force High-Speed Uart Clock X2, X4, or X8 J3, 4 Enable Scratchpad Register SPAD, J2Clock Rate and Optional Registers Clock multiplier jumper options Hardware Installation Jumper/connector locationsChannel Address Range Enabling the Special Registers Interrupt Status RegisterDlab Bit Spad Jumper Register selected for Bit DescriptionQuatech Modem Control Register Quatech Modem Control RegisterWrite Read Options RegisterBit Name Description Clock Rate Multiplier Clock Rate Uart Clock Maximum Data Multiplier FrequencyWindows Configurations Windows MillenniumWindows Windows Page Windows Windows NT Viewing Resources with Device Manager Two-Port RS-422/RS485 Serial Adapter Page DSCLP-200/300 Two-Port RS-422/485 Serial Adapter Page Page Page Page DOS and other operating systems Other Operating SystemsOS/2 QTPCI.EXE QTPCI.EXE Expert Mode display External Connections Jumper/Channel correspondenceRTS/CTS Handshake RclkTclk AUXIN/AUXOUT LoopbackHalf-Duplex/Full-Duplex/Auto-Toggle Selection Half/full-duplex and Auto-Toggle selection Termination Resistors RS-422/485 Line termination resistance valuesDSCLP-200/300 connector definitions RS-422/485 Peripheral ConnectionPCI Resource Map INTA#Specifications With 64-byte FIFOs optionalCannot communicate with other equipment TroubleshootingComputer will not boot up DSCLP/SSCLP-200/300