Patton electronic Model 3088/I manual Industry Canada Notice, CE Declaration of Conformity

Page 48

3088/I Getting Started Guide

A • Compliance information

 

 

able protection from such interference in a commercial installation. However, there is no guarantee that inter- ference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equip- ment and receiver are on different branches).

Industry Canada Notice

This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that regis- tration was performed based on a Declaration of Conformity indicating that Industry Canada technical speci- fications were met. It does not imply that Industry Canada approved the equipment.

This Declaration of Conformity means that the equipment meets certain telecommunications network protec- tive, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be con- nected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment mal- functions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.

CE Declaration of Conformity

We certify that the apparatus identified in this document conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity.

The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.

Authorized European Representative

D R M Green

European Compliance Services Limited.

Oakdene House, Oak Road

Watchfield,

Swindon, Wilts SN6 8TD, UK

Industry Canada Notice

48

Image 48
Contents RocketLink-G G.SHDSL NTU Mailsupport@patton.com Summary Table of Contents Table of Contents Installation & operation Factory replacement parts and accessories RS-232 console interface pin assignments List of Figures List of Tables About this guide AudienceStructure Precautions Impaired functioningSafety when working with electricity General observationsTypographical conventions used in this document General conventionsChapter contents General informationFeatures RocketLink-G 3088/I overviewInitial configuration Power up the NTU AC power-upDC power-up IntroductionPower-up indication Configure the IP addressConnect a PC and log Modify the IP address Connect to the local IP networkLog onto the web management interface Connect the G.SHDSL portRear view of 3088/I showing DSL RJ-11 jack Shdsl config and status DSL configuration DSL ParametersDSL Error Monitor Configuration DSL Error Monitor ConfigurationShdsl Status Run-Time StatisticsDSL Line Error Counters Local Interface Error CountersClearing Error Counters Clearing the error countersEthernet & WAN PPP Config and status IP configuration PPP configurationEthernet port configuration Ethernet Basic Port AttributesEthernet Advanced Port Attributes Ethernet performance statisticsConfigurable Ethernet parameters Installation & operation Installation Power-upConnecting the twisted-pair interface OperationLED status indicators Power YellowWAN LEDs Ethernet LEDs 100M YellowSystem Management RocketLink-G Plug ‘n’ Play 3088Reset for Factory Default Saving the configurationConsole Authentication Backing up and restoring saved configurationsSystem Software Upgrade Upgrading software on the 3088/IDiagnostic tools System tools for testing LED status monitor & definitionPing & Traceroute Contacting Patton for assistance Warranty coverage Contact informationPatton support headquarters in the USA Out-of-warranty service RMA numbersAppendix a Compliance information Safety ComplianceFCC Part 68 Acta Statement Radio and TV Interference FCC PartIndustry Canada Notice CE Declaration of ConformityAuthorized European Representative Appendix B Specifications General characteristics Shdsl characteristicsEthernet Protocol supportSerial connector DiagnosticsManagement 10Base-T/100Base-TX interfacePower VDC power supplyEthernet 100M Ethernet TxDimensions Line InterfaceEnvironment Shdsl Physical connection & Transmission LineAppendix C Factory replacement parts and accessories Factory replacement parts and accessories Model # DescriptionAppendix D RJ-11 non-shielded DSL port RJ-11 non-shielded DSL port Appendix E RJ-45 shielded 10/100 Ethernet port RJ-45 shielded 10/100 Ethernet port Appendix F RS-232 console interface Pin assignments RJ-45 non-shielded Connector EIA-561 RS-232 console interface pin assignments