Operating Precautions

Make sure the mains voltage is correct and the same as that printed on the rear of the amplifier. Damage caused by connecting the amplifier to improper AC voltage is not covered by any CS® Series warranty. See the Connecting Power section for more information on voltage requirements.

Note: Always turn off and disconnect the amplifier from mains voltage before making audio connections. Also, as an extra precaution, have the attenuators turned down during power-up.

Before powering up, turn the attenuator controls down to prevent speaker damage if there is a high signal level at the inputs. Always use high-quality input and speaker cables to ensure trouble-free operation. Most intermittent problems are caused by faulty cables.

Consult the Wire Gauge Charts (page 9) to determine proper gauges for differing load impedances and cable lengths. Cable resistance robs amplifier power in two ways: power lost directly to resistance (I2R loss) and by increasing the impedance of the load presented to the amplifier, thereby decreasing the power demanded of the amplifier.

Connecting Inputs

Input connections are made via the three-pin XLR (pin 2+) or 6.3 mm plug “combi” connectors on the rear panel of the amplifier. The inputs are actively balanced and the overload point is high enough to accept the maximum output level of virtually any signal source.

Connecting Outputs

The CS 800x4 has one Speakon® connector per channel. The connectors for channels 1 and 3 include the output of channels 2 and 4 to facilitate Bridged mode operation.

Connecting Power

CS Series amplifier power requirements are rated at 1/8 power (typical music conditions) and 1/3 power (extreme music conditions). The maximum power current draw rating is limited only by the front panel circuit breaker. Consult the specifications in the Appendices section for figures on the current that each amplifier will demand. Unless otherwise specified when ordered, Peavey amplifiers shipped to customers are configured as follows:

North America

-

120VAC/60Hz

Europe, Asia, Australia -

230/240VAC/60-50Hz

South America

-

120VAC/60Hz or 240VAC/50Hz

Note: Always turn off and disconnect the amplifier from mains voltage before making audio connections. As an extra precaution, have the attenuators turned down while powering up.

WARNING

THE ON/OFF SWITCH IN THIS APPARATUS

DOES NOT BREAK BOTH SIDES OF THE MAINS.

HAZARDOUS ENERGY MAY BE PRESENT INSIDE

THE ENCLOSURE WHEN THE POWER SWITCH IS

IN THE OFF POSITION.

8

Image 8
Contents Page Page Important Safety Instructions Bewahren SIE Diese Sicherheitshinweise AUF Gardez CES Instructions Guarde Estas Instrucciones Power Amplifier UnpackingMounting Cooling RequirementsOperating Precautions Connecting InputsConnecting Outputs Connecting PowerWire Gauge Charts Operation Modes Stereo OperationParallel Operation Bridged Mono OperationFront Panel Rear Panel Switches & Controls AC Power Circuit BreakersMode Select Switch Input AttenuatorsFront Panel Indicators PWR LEDProtection Features RampUp Signal Control Speaker ProtectionAmplifier Maintenance and User Responsiblity Service / Warranty InformationPower Amplifier Power Amplifier Endstufe AuspackenMontage KühlanforderungenEinleitung Sicherheitshinweise für den BetriebAnschluss der Eingänge Anschluss der AusgängeKabelstärkentabellen Betriebsmodi StereobetriebParallelbetrieb Bridged-Mono-BetriebVorderseite Rückseite Schalter und Regler Wechselstrom-Netzschalter/LeistungsschalterEingangsdämpfer MODE-WahlschalterVorderseite Anzeigen Schutzfunktionen Einschalt-/Ausschaltschutz RampUp-SignalregelungLautsprecherschutz Wartung Des Verstärkers Und Verantwortung Des Nutzers Kundendienst Informationen zur GarantieEndstufe Specifications Installation Amplificateurs de PuissanceDéballage RefroidissementPrécautions d’Utilisation Connecter les entrées de votre unité InputsConnecter les entrées de votre unité Outputs Alimentation ElectriqueLa Charte De Dimensions Des Cables Modes d’Opération StéréoParallèle PontPanneau Avant Panneau Arrière Sélecteurs & Contrôles Panneau Avant Indicators Systèmes de Protection Protection des Haut-Parleurs Système RampUp contrôle de montée en puissanceMaintenance et Responsabilité d’Utilisateur Réparation/Informations de GarantieAmplificateur de Puissance Power Amplifier Etapa de Potencia DesembalajeMontaje Requisitos de enfriamientoIntroducción Precauciones de OperaciónConectando Entradas Conectando SalidasTablas de Calibre del Cable Modos de Operación Operación EstéreoOperación en Paralelo Operación en Mono BridgedPanel Frontal Panel Trasero Interruptores & Controles Breakers del circuito de alimentación ACAtenuadores de Entrada Interruptor de Selección de ModoPanel Frontal Indicadores LED PWRCaracterísticas de Protección Protección de los altavoces Control de Señal RampUpMantenimiento del amplificador y responsabilidad del usuario Información sobre servicio post-venta y garantíaEtapa de Potencia Etapa de Potencia Peavey Electronics Corporation Limited Warranty 2005