Introduction
Operating Precautions
Make sure the mains voltage is correct and the same as that printed on the rear of the amplifier. Damage caused by connecting the amplifier to improper AC voltage is not covered by any CS® Series warranty. See the Connecting Power section for more information on voltage requirements.
Note: Always turn off and disconnect the amplifier from mains voltage before making audio connections. Also, as an extra precaution, have the attenuators turned down during
Before powering up, turn the attenuator controls down to prevent speaker damage if there is a high signal level at the inputs. Always use
Consult the Wire Gauge Charts (page 9) to determine proper gauges for differing load impedances and cable lengths. Cable resistance robs amplifier power in two ways: power lost directly to resistance (I2R loss) and by increasing the impedance of the load presented to the amplifier, thereby decreasing the power demanded of the amplifier.
Connecting Inputs
Input connections are made via the
Connecting Outputs
The CS 800x4 has one Speakon® connector per channel. The connectors for channels 1 and 3 include the output of channels 2 and 4 to facilitate Bridged mode operation.
Connecting Power
CS Series amplifier power requirements are rated at 1/8 power (typical music conditions) and 1/3 power (extreme music conditions). The maximum power current draw rating is limited only by the front panel circuit breaker. Consult the specifications in the Appendices section for figures on the current that each amplifier will demand. Unless otherwise specified when ordered, Peavey amplifiers shipped to customers are configured as follows:
North America | - | 120VAC/60Hz |
Europe, Asia, Australia - | ||
South America | - | 120VAC/60Hz or 240VAC/50Hz |
Note: Always turn off and disconnect the amplifier from mains voltage before making audio connections. As an extra precaution, have the attenuators turned down while powering up.
WARNING
THE ON/OFF SWITCH IN THIS APPARATUS
DOES NOT BREAK BOTH SIDES OF THE MAINS.
HAZARDOUS ENERGY MAY BE PRESENT INSIDE
THE ENCLOSURE WHEN THE POWER SWITCH IS
IN THE OFF POSITION.
8