DC Power Interface

 

Interface

Screw-type terminal block

 

1. Two pairs for power wire cascading

 

2. One pair for power failure relay output

 

DC Jack (-D6.3mm/+D2.0mm)

Operating Input Voltages

+7V~+30V(+5%)

Power consumption

2.25W @+7.5VDC input

 

2.3W @+24VDC input

 

2.5W @+30VDC input

Basic Information

 

Conversion

Full wire speed

 

1000Mbps - 1,488,00pps at 64-byte packets

Packet Types

Transparent and no modification for

 

- IEEE 802.3 standard packets

 

- IEEE 802.1Q VLAN tagged packets

Packet Length

No limit

Mechanical

 

Dimension (base)

W28mmxD82mmxH95mm

Housing

Enclosed metal with no fan

Mounting Support

DIN-rail mounting, Panel mounting

Weight

252g

Environmental

 

Operating Temperature

Typical -20oC ~ 70oC (model dependent)

Storage Temperature

-20oC ~ 85oC

Relative Humidity

5% ~ 90%

-9-

Image 9
Contents Media Converters 1000BASE-T to 1000BASE-XInternational United StatesEthernet is a registered trademark of Xerox Corp Table of Contents Introduction Features Specifications LEDIndicators Twisted-Pair Interface Copper PortFiber Optic Interface Fiber Port Basic Information DC Power InterfaceMechanical EnvironmentalCE/EMC CertificateLink Fault Pass Through Function Special FunctionsAutoMDI/MDI-XFunction Far End Fault Function Unpacking InstallationSafety Cautions DIN-Rail Mounting Page Panel Mounting Screw locations and final dimension are shown below Using Terminal Blocks Applying PowerPage Using DC Power Jack Power Failure Relay Output Network Cables Making Twisted Pair Copper Port ConnectionInstalling SFP Fiber Transceiver Connecting Fiber CablesMaking Fiber Port Connection LED Indicators Model Specifications Appendix Model Optical Specifications