As an alternative to controlling the channels to be displayed from the control panel you can also control them by selecting the desired channels from the list of channel gains shown at the right hand side of the display window.

Pressing the Finder button at the top of the control panel will identify the module associated with the current channel. When the finder button is depressed, the LED on the front panel lights up yellow on the digitizer module with the current channel.

4.2.3. Numeric Editor

The numeric editor is shown in the control window at locations where numeric values are set. The Acqiris Numeric Editor enables easy input of numeric values,

particularly those ranging over many decades. The numeric value can be changed in multiple ways.

A number can be typed directly into the white number display area or alternatively, the Acqiris Numeric Editor may be used. In order to use the Acqiris Numeric Editor, click on the green numeric editor icon at the left of the number display. A numeric editor control will appear as shown.

The methods to change the values are:

1.Increment or decrement any digit with the arrow buttons by pressing the increment or decrement button. When the button is held down, the digit will continue to increment or decrement automatically.

2.Click on a digit and drag the mouse up or down to increase or decrease the value.

3.Type a new value with the keyboard for any highlighted digit.

The value is constrained to fall within its allowed range whenever the user attempts to enter a larger or smaller value. Digits that are below the resolution or granularity cannot be modified. A

message is displayed in the numeric setting control window when the pointer

is positioned over a digit that is below the allowed granularity and cannot be changed.

4.2.4. Keyboard shortcuts

Two shortcuts have been defined to simplify applying changes of a parameter to a group of channels. When the mouse is over the control of a channel parameter -

ƒ's' can be used to set the current value to all channels of all available instruments

ƒ'c' can be used to set the current value to all channels of the current instrument. Other shortcuts are:

ƒ'Ctrl-S' as a synonym for 'Save Setup'

ƒ'Ctrl-R' as a synonym for 'Recall Setup'

ƒ'Ctrl-C' as a synonym for Calibrate all (active) instruments'

ƒ'Ctrl-E' functions as a toggle between 'Internal Clock' and 'External Clock' operation.

4.2.5. Input Voltage Scale, Offset and Coupling

Settings for input voltage scale, offset, coupling and impedance are available in the portion of the control panel shown to the right. The selected channel is shown on the upper section of the display. Only this channel will be affected by changes in any settings on the control panel. The input voltage scale is set by one of three possible methods:

User Manual: Family of 8-bit Digitizers

Page 44 of 66

Image 44
Contents Agilent Acqiris Family BIT Digitizers XZ001USA Contents OUT of the BOX Running the Acqirislive Application Conventions Used in This Manual Using this ManualMessage to the User Disclaimer and Safety Packaging and HandlingWarranty System RequirementsMaintenance Transport & ShippingCleaning Disposal and RecyclingIC414 Installation 1. IC414 Hardware installation hints 2. IC414 Windows software installationMultiple Versions Installing the Software under WindowsInstallation Page Page Page Page Page Page Page Page Page Installing the Software for Linux Kernel Mode Driver Compilation ƒ cd linuxdriverpciEnvironment variables for the Firmware Installing the HardwareSpecial cases After Restarting Windows Windows XPPage LabVIEW RT Installing the IVI-COM/C Driver Distribution for Windows 2000/XP and LinuxDP110 Block Diagram OverviewChannel Input Coupling ImpedanceInput Protection Mezzanine Front-endOffset Particularities DC Accuracy and Linearity Vertical ResolutionInput Voltage and Offset Using Probes Data AcquisitionSingle and Sequence Acquisition Modes Sampling RateAcquisition Memory Timing Timebase RangeCombining channels TriggerTrigger Coupling Trigger LevelEdge Trigger Slope Window TriggerExternal Clock and Reference Pre- and Post-Trigger DelayTrigger Status Special Front Panel Input and OutputDP1400 & DC271-FAMILY Internal CalibrationASBus Frequency Counter mode External Trigger Output DP1400 & DC271-FAMILYPCI DMA Operating Temperature DimensionsSafety Environmental and PhysicalRunning the AcqirisLive Application Getting Started with AcqirisLiveControl Panel Mode Control Panel and FunctionsDisplaying Multiple Traces Input Voltage Scale, Offset and Coupling Numeric EditorKeyboard shortcuts Acquisition Mode Using digitizers of different models simultaneously Timebase and MemoryDisplay Features, Zoom and Persistence Segmented MemoryStore, Autostore and Conversion of Waveforms SetupTop Line Menu of AcqirisLive Page Calibrate Combine channelsExternal 10 MHz Reference and External Clock Additional Waveform InformationDisplay Features Command Line SwitchesAvailable Switches Operation ModeTransient Recorder mode Buffer sizeBanks for Smar CalibrationSimulation Mode Temperature UpdateAcquisition State Multi-instrumentsWho needs a Geographical Map of Modules When should the GeoMapper Application be usedHow to run GeoMapper Page Page Page Appendix B ASBus2 for PCI Digitizers Page Page Page Page Page Appendix H XP104 Fan Unit for DP1400 Page Appendix I XP105 Fan Unit for DP1400