Delta operation manual Basic Settings, „ Setting up DVPEN01-SL basics

Page 22

Ethernet Communication Module DVPEN01-SL

5.2Basic Settings

The basic settings include parameters as module name, language, enabling Modbus TCP and time correction.

„Setting up DVPEN01-SL basics

1.Module Name:

There can be many DVPEN01-SL modules in the network. Thus, you can set up a module name for each module to identify the module when you need to use them.

2.Module Language:

You can select a language for each module name, and the windows will be displayed in the selected language.

3.Enable Modbus TCP:

To enable or disable Modbus TCP. When Modbus TCP is disabled, WPLSoft will not be able to upload or download.

4.Enable time correction:

DVPEN01-SL adopts NTP (Network Time protocol), which means it can acquire correct time automatically from the time server in the network and correct the RTC in the MPU every fixed period of time to ensure correct time in the MPU. The default setting of this function is “disable”.

5.Start Daylight Saving Time:

Daylight Saving Time; also known as summer time is a conventional local time adopted by many countries in the world on a seasonal basis. Most commonly DST is obtained by adjusting the official local time forward, by one hour, for the spring, summer, and early autumn periods. Daylight Saving Time is not implemented in Taiwan; therefore, you do not need to check this item.

6.Time Server:

IP address of the time server. You can acquire correct time from the time server to correct the time in the MPU.

20

DVP-PLC Operation Manual

Image 22
Contents DVPEN01-SL Page Table of Contents Application Examples Specifications FunctionsDimension Product ProfilesInstallation LED IndicatorsRJ-45 PIN Definition Control Register CR Control Registers in DVPEN01-SLEthernet Communication Module DVPEN01-SL Explanations on CR „ E-mail Functions„ Data Exchange Ethernet Communication Module DVPEN01-SL „ Sending Modbus TCP Instruction Ethernet Communication Module DVPEN01-SL Numbering of Left-Side Modules „ RTU MappingSetting up Communication & Searching for Modules „ Communication settings„ Broadcast search „ Designating model to search Ethernet Communication Module DVPEN01-SL „ Searching by IP address „ Opening DVPEN01-SL setup page by RS-232 Basic Settings „ Setting up DVPEN01-SL basicsNetwork Settings „ Setting up static IP of the PCEthernet Communication Module DVPEN01-SL „ Setting up DVPEN01-SL Network DhcpSetting up E-Mails „ Setting up DVPEN01-SL mail„ Setting up DVPEN01-SL data exchange Data Exchange„ The settings RTUIP Filter „ Setting up IP filterStatic ARP Table „ Setting up static ARP table Setting up Password„ Setting up DVPEN01-SL password Returning to Default Setting „ DVPEN01-SL returning to default settingSetting up IP and Communicating through WPLSoft Application ExamplesEthernet Communication Module DVPEN01-SL Open Basic setup Switch to Network setup Connecting the PC with DVPEN01-SL through LAN DVPEN01 DVP-PLC Ethernet Communication Module DVPEN01-SL Ethernet Communication Module DVPEN01-SL Setting up Password and Clearing Password Ethernet Communication Module DVPEN01-SL After the password is cleared, you can modify the parameters IP Filter Protection Ethernet Communication Module DVPEN01-SL Setting up Static ARP Table Ethernet Communication Module DVPEN01-SL Application of E-Mail Application of Data Exchange ExplanationsEthernet Communication Module DVPEN01-SL TRD Application of Data Exchange Ethernet Communication Module DVPEN01-SL Ethernet Communication Module DVPEN01-SL From Explanations Data exchange will be executed every one second Application of Modbus TCP Master RTU Mapping Ethernet Communication Module DVPEN01-SL Ethernet Communication Module DVPEN01-SL