CH Tech EM405D user manual Installation Unpacking and Inspection, Handling Precautions

Page 11

2.0INSTALLATION

2.1UNPACKING AND INSPECTION

Verify that there has been no damage to the shipping container. If damage exists then the container should be retained, as it will provide evidence of carrier caused problems. Such problems should be reported to the carrier immediately as well as to C&H. If there is no damage to the shipping container, carefully remove the instrument from its box and inspect for any signs of physical damage. If damage exists, report immediately to C&H.

2.2 HANDLING PRECAUTIONS

The components used in the EM405D are static sensitive. Damage may occur if proper static precautions are not taken. Installation of M-modules should only be done at a properly grounded static free workstation.

CAUTION: Read the entire User's Manual before proceeding with the installation and application of power.

2.3 INSTALLATION OF M-MODULES

To install modules, first remove power from the carrier. Remove the front panel cover by removing the two screws located at the sides of the panel. Do not remove the screws located on the bottom of the enclosure. Slide the PCB out of enclosure. Install M-modules by firmly pressing the connector on the M-module together with the connector on the carrier as shown in Figure 2. Secure the module through the holes in the PCB using screws provided with the M- module.

WARNING: The EM405D supports M-modules that use two or three row interface connectors. When using M-modules with only two rows, row C of connector (rear row) is left unconnected.

M/MA-Module

A B C

Carrier

Figure 2. M-module Installation

5

Image 11
Contents H E R N E T Copyright 2004 by C&H Technologies, Inc CopyrightDocument Revision Notice Introduction Operating Instructions Table of Contents General DescriptionInstallation Functional DescriptionList of Tables EM405D Ethernet M-Module CarrierPurpose of Equipment Features and SpecificationsKey Features Maximum Ratings SpecificationsBus Compliance ElectricalMechanical EnvironmentalApplicable Documents Installation of M-MODULES Installation Unpacking and InspectionHandling Precautions MA Configuration Diagram Ethernet Interface Functional Description GeneralRear Panel Power ConversionModule Interface Front Panel Front PanelPage IP Address Configuring the Ethernet InterfaceOperating Instructions General Recommendation Default subnet mask is GatewayDefault gateway address is Port Numbers Default setting is Auto-Scan Telnet x.x.x.x Performing the Configuration Wireless Ethernet Wi-Fi Page Table II. Status Code SC Table I. Command SummaryError Handling Communicating with the Carrier and M-MODULESPage Read Data command Write Data commandStarting address + block size * word size Block AccessNumber of bytes = number of blocks * block size * word size 0x50 md as ws ad ai nh nl bs Table III. Register Summary 5 EM405D Configuration/Status RegistersFirmware Version Reset Error & Manufacturer IdentificationDevice Identification Hardware VersionFan Control & Temperature Status Reset & Trigger ControlFollowing values would be invalid Controlling the TriggersFAN and Temperature Control Page Figure A-1 -Pin Dsub Connector Page Table B-1. Ethernet Interface Default Settings Appendix B Wired Ethernet Default SettingsOn Passive Connection True CPU Performance High Page Wireless LAN Settings Table C-1. Wireless Ethernet Configuration Default SettingsCurrent Port Profile TCP Sockets Gpio Page T E S Page Comments Readers Comment FormInstructions