CH Tech EM405D user manual Current Port Profile TCP Sockets

Page 42

Table C-1. Wireless Ethernet Configuration Default Settings. (continued)

Enable Line Printer Daemon (LPD)

True

- Port

515

Enable RealPort

True

- Port

771

Enable Remote Login (rlogin)

True

- Port

513

Enable Remote Shell (rsh)

True

- Port

514

Enable SNMP

True

- Port

161

Enable Telnet

True

- Port

23

 

 

Advanced Network Settings

 

Enable AutoIP address assignment

True

RTS Threshold

2347

Fragmentation Threshold

2346

 

 

Serial Port

 

Port Profile Settings

 

Current Port Profile

TCP Sockets

 

 

TCP Server Settings

 

Enable Telnet access using TCP Port

False

- Port

N/A

Enable Raw TCP access using TCP Port

True

- Port**

10001

Enable Secure Socket access using TCP Port

False

- Port

N/A

 

 

TCP Client Settings

 

Automatically establish TCP connections

False

 

 

Basic Serial Settings

 

Description

blank

Baud Rate

230400

Data Bits

8

Parity

None

Stop Bits

1

Flow Control

None

**The EM405D will operate with any port number; however, many software applications expect the port to be set to the default as shown in this table. Changing the port number will not render the EM405D inoperable but may render these software applications inoperable.

C-2

Image 42
Contents H E R N E T Copyright Copyright 2004 by C&H Technologies, IncDocument Revision Notice Introduction Functional Description Table of Contents General DescriptionInstallation Operating InstructionsEM405D Ethernet M-Module Carrier List of TablesFeatures and Specifications Key FeaturesPurpose of Equipment Specifications Maximum RatingsEnvironmental ElectricalMechanical Bus ComplianceApplicable Documents Installation Unpacking and Inspection Handling PrecautionsInstallation of M-MODULES MA Configuration Diagram Functional Description General Ethernet InterfacePower Conversion Module InterfaceRear Panel Front Panel Front PanelPage Configuring the Ethernet Interface Operating Instructions GeneralIP Address Default subnet mask is Gateway Default gateway address is Port NumbersRecommendation Default setting is Auto-Scan Telnet x.x.x.x Performing the Configuration Wireless Ethernet Wi-Fi Page Communicating with the Carrier and M-MODULES Table I. Command SummaryError Handling Table II. Status Code SCPage Write Data command Read Data commandBlock Access Starting address + block size * word sizeNumber of bytes = number of blocks * block size * word size 0x50 md as ws ad ai nh nl bs 5 EM405D Configuration/Status Registers Table III. Register SummaryHardware Version Reset Error & Manufacturer IdentificationDevice Identification Firmware VersionReset & Trigger Control Fan Control & Temperature StatusControlling the Triggers Following values would be invalidFAN and Temperature Control Page Figure A-1 -Pin Dsub Connector Page Appendix B Wired Ethernet Default Settings Table B-1. Ethernet Interface Default SettingsOn Passive Connection True CPU Performance High Page Table C-1. Wireless Ethernet Configuration Default Settings Wireless LAN SettingsCurrent Port Profile TCP Sockets Gpio Page T E S Page Readers Comment Form CommentsInstructions