CH Tech EM405D Operating Instructions General, Configuring the Ethernet Interface, IP Address

Page 17

4.0OPERATING INSTRUCTIONS

4.1GENERAL

The EM405D is controlled through the Ethernet interface using the TCP/IP protocol to carry a simple command structure to the module. The carrier contains a set of software controlled registers that allow the user to request status from the carrier, identify the carrier, and configure the carrier. All other M/MA controls are dependent on the specific M-module(s) that reside on the carrier.

4.2 CONFIGURING THE ETHERNET INTERFACE

The Ethernet interface must be properly configured to work on the user’s network. The flexibility of the EM405D’s Ethernet interface allows it to be used in a large number of possible network configurations. The unit is delivered with a default configuration that may or may not be appropriate for the user’s network. It is up to the user and the user’s network administrator to use the information provided throughout this section to determine what configuration is best for the given network.

4.2.1 IP Address

The EM405D must have a unique IP address before it can communicate on a network. There are several options for assigning an IP address to the unit. The option to choose is dependant upon the type of network for which the EM405D is being configured.

DHCP: The Dynamic Host Control Protocol (DHCP) allows the module to dynamically retrieve an IP address from a DHCP server at power-up. If DHCP is used, the EM405D may have a different IP address assigned each time it is powered on or connected to the network. For the wired EM405D, DHCP is automatically enabled if the IP address is set to 0.0.0.0. For the wireless EM405D, DHCP is a separate setting. DHCP enabled is the default setting.

AutoIP: The AutoIP protocol allows the module to automatically assign itself an IP address on networks that do not have a DHCP server. If a DHCP server is not found, the EM405D will select an IP address from the AutoIP reserved range (168.254.0.1 to 168.254.255.1). The unit will then send out an address resolution (ARP) request on the network to determine if the chosen address is already in use. If another device is using the selected IP address then the EM405D will select another address from the range and repeat the address resolution request. This continues unit the device finds an IP address that is not in use. For the wired EM405D, manually setting the IP address to 0.0.0.0 enables AutoIP as well as DHCP and manually setting the IP address to 0.0.1.0 will disable AutoIP but keep DHCP enabled. For the wireless EM405D both AutoIP and DHCP have separate enable/disable settings. AutoIP enabled is the default setting.

Static: For the wired EM405D, manually setting the IP address to something other than 0.0.0.0 will configure the EM405D to use the IP address specified. For the wireless EM405D DHCP must be disabled and the IP address must be manually set. The configured IP address will remain static even after power is removed from the module. For proper operation, the IP address must be chosen according to the network the module is being connected to.

11

Image 17
Contents H E R N E T Copyright 2004 by C&H Technologies, Inc CopyrightDocument Revision Notice Introduction Installation Table of Contents General DescriptionFunctional Description Operating InstructionsList of Tables EM405D Ethernet M-Module CarrierPurpose of Equipment Features and SpecificationsKey Features Maximum Ratings SpecificationsMechanical ElectricalEnvironmental Bus ComplianceApplicable Documents Installation of M-MODULES Installation Unpacking and InspectionHandling Precautions MA Configuration Diagram Ethernet Interface Functional Description GeneralRear Panel Power ConversionModule Interface Front Panel Front PanelPage IP Address Configuring the Ethernet InterfaceOperating Instructions General Recommendation Default subnet mask is GatewayDefault gateway address is Port Numbers Default setting is Auto-Scan Telnet x.x.x.x Performing the Configuration Wireless Ethernet Wi-Fi Page Error Handling Table I. Command SummaryCommunicating with the Carrier and M-MODULES Table II. Status Code SCPage Read Data command Write Data commandStarting address + block size * word size Block AccessNumber of bytes = number of blocks * block size * word size 0x50 md as ws ad ai nh nl bs Table III. Register Summary 5 EM405D Configuration/Status RegistersDevice Identification Reset Error & Manufacturer IdentificationHardware Version Firmware VersionFan Control & Temperature Status Reset & Trigger ControlFollowing values would be invalid Controlling the TriggersFAN and Temperature Control Page Figure A-1 -Pin Dsub Connector Page Table B-1. Ethernet Interface Default Settings Appendix B Wired Ethernet Default SettingsOn Passive Connection True CPU Performance High Page Wireless LAN Settings Table C-1. Wireless Ethernet Configuration Default SettingsCurrent Port Profile TCP Sockets Gpio Page T E S Page Comments Readers Comment FormInstructions