3.3 FRONT PANEL

The front panel of the EM405D contains two openings for access to the M-modules’ front panel connections and three LED indicators as shown in Figure 6. As mandated by the M-module specification, each M-module should provide a front panel connector containing the M-module I/O signals. The two openings on the EM405D’s front panel provide access to these connectors. The functions of the three front-panel LED indicators are:

PWR: indicates that power is supplied to the module and that the power switch is ON. The units should be operating normally.

A, B: indicates that M-module A or B is currently being accessed. The LED will illuminate temporarily each time the module is accessed by the host software.

 

EM405D ETHERNET M-MODULE CARRIER

PWR

 

B

A

Figure 6. Front Panel

9

Image 15
Contents H E R N E T Copyright 2004 by C&H Technologies, Inc CopyrightDocument Revision Notice Introduction Operating Instructions Table of Contents General DescriptionInstallation Functional DescriptionList of Tables EM405D Ethernet M-Module CarrierFeatures and Specifications Key FeaturesPurpose of Equipment Maximum Ratings SpecificationsBus Compliance ElectricalMechanical EnvironmentalApplicable Documents Installation Unpacking and Inspection Handling PrecautionsInstallation of M-MODULES MA Configuration Diagram Ethernet Interface Functional Description GeneralPower Conversion Module InterfaceRear Panel Front Panel Front PanelPage Configuring the Ethernet Interface Operating Instructions GeneralIP Address Default subnet mask is Gateway Default gateway address is Port NumbersRecommendation Default setting is Auto-Scan Telnet x.x.x.x Performing the Configuration Wireless Ethernet Wi-Fi Page Table II. Status Code SC Table I. Command SummaryError Handling Communicating with the Carrier and M-MODULESPage Read Data command Write Data commandStarting address + block size * word size Block AccessNumber of bytes = number of blocks * block size * word size 0x50 md as ws ad ai nh nl bs Table III. Register Summary 5 EM405D Configuration/Status RegistersFirmware Version Reset Error & Manufacturer IdentificationDevice Identification Hardware VersionFan Control & Temperature Status Reset & Trigger ControlFollowing values would be invalid Controlling the TriggersFAN and Temperature Control Page Figure A-1 -Pin Dsub Connector Page Table B-1. Ethernet Interface Default Settings Appendix B Wired Ethernet Default SettingsOn Passive Connection True CPU Performance High Page Wireless LAN Settings Table C-1. Wireless Ethernet Configuration Default SettingsCurrent Port Profile TCP Sockets Gpio Page T E S Page Comments Readers Comment FormInstructions