CH Tech EM405D user manual Introduction

Page 4

INTRODUCTION

This manual describes the operation and use of the C&H Model EM405D Ethernet M-Module Carrier (Part Number 11028850). This instrument is one of a number of M-module carriers provided by C&H.

Contained within this manual are the physical and electrical specifications, installation and startup procedures, functional description, and configuration and programming guidelines to adequately use the product.

Software drivers for an installed M/MA module may be provided by the M/MA module manufacturer. Some drivers may require modification to operate correctly with the communication protocol and the addressing methodology used by the EM405D. To support initial operation and application software development, C&H provides a software application called Interactive Mezzanine Control (IMC). The application provides immediate access and control of any M/MA module residing on an EM405D. IMC can be downloaded from the support section of C&H’s website www.chtech.com.

iv

Image 4
Contents H E R N E T Copyright Copyright 2004 by C&H Technologies, IncDocument Revision Notice Introduction Table of Contents General Description InstallationFunctional Description Operating InstructionsEM405D Ethernet M-Module Carrier List of TablesKey Features Features and SpecificationsPurpose of Equipment Specifications Maximum RatingsElectrical MechanicalEnvironmental Bus ComplianceApplicable Documents Handling Precautions Installation Unpacking and InspectionInstallation of M-MODULES MA Configuration Diagram Functional Description General Ethernet InterfaceModule Interface Power ConversionRear Panel Front Panel Front PanelPage Operating Instructions General Configuring the Ethernet InterfaceIP Address Default gateway address is Port Numbers Default subnet mask is GatewayRecommendation Default setting is Auto-Scan Telnet x.x.x.x Performing the Configuration Wireless Ethernet Wi-Fi Page Table I. Command Summary Error HandlingCommunicating with the Carrier and M-MODULES Table II. Status Code SCPage Write Data command Read Data commandBlock Access Starting address + block size * word sizeNumber of bytes = number of blocks * block size * word size 0x50 md as ws ad ai nh nl bs 5 EM405D Configuration/Status Registers Table III. Register SummaryReset Error & Manufacturer Identification Device IdentificationHardware Version Firmware VersionReset & Trigger Control Fan Control & Temperature StatusControlling the Triggers Following values would be invalidFAN and Temperature Control Page Figure A-1 -Pin Dsub Connector Page Appendix B Wired Ethernet Default Settings Table B-1. Ethernet Interface Default SettingsOn Passive Connection True CPU Performance High Page Table C-1. Wireless Ethernet Configuration Default Settings Wireless LAN SettingsCurrent Port Profile TCP Sockets Gpio Page T E S Page Readers Comment Form CommentsInstructions