CH Tech EM405D user manual Purpose of Equipment, Features and Specifications, Key Features

Page 7

1.0 GENERAL DESCRIPTION

The EM405D Ethernet M-Module carrier provides complete Ethernet connectivity to up to two industry standard single-wide or one double-wide M or MA modules. The carrier provides full access to the M/MA module I/O space via the standard TCP/IP networking protocol. M-module triggers are also fully supported allowing them to be connected externally to a 9-pin DSUB connector or to an adjacent M-module. A simple command structure eases software integration and allows reset, identification, control, and configuration of the carrier and M-modules. For a complete list of M-modules compatible with the EM405D carrier, visit the mezzanine section of www.mezzanines.org, or www.vita.com.

Figure 1. EM405D Ethernet M-Module Carrier

1.1 PURPOSE OF EQUIPMENT

The EM405 easily interfaces a VITA 12-199x standard M/MA Module to a typical Ethernet network. The carrier allows the numerous functions available in the M-Module mezzanine format to be remotely located near the unit-under-test, easing many system integration issues. Over 100 M/MA modules are available from numerous manufacturers.

1.2 FEATURES AND SPECIFICATIONS

1.2.1 Key Features

Supports two ANSI/VITA 12-1996 compliant single-wide M or MA-modules or one double-wide module

Ethernet 10Base-T, 100Base-TX (Auto-Sensing) or Wi-Fi 802.11b

Rugged steel/aluminum enclosure (5.6"W × 8.5"D × 1.5"H)

+12V power input through standard 2.5mm jack or 9-pin DSUB

Variable speed forced air cooling with software temperature status

D16 M-module accesses supported

Flexible block access command provides rapid sequential and FIFO data accesses

External trigger input/output and inter-module triggers supported

Isolated and filtered +5V, +12V, and -12V supplies for each M-module

Interactive Mezzanine Control (IMC) software available

1

Image 7
Contents H E R N E T Copyright 2004 by C&H Technologies, Inc CopyrightDocument Revision Notice Introduction Operating Instructions Table of Contents General DescriptionInstallation Functional DescriptionList of Tables EM405D Ethernet M-Module CarrierKey Features Features and SpecificationsPurpose of Equipment Maximum Ratings SpecificationsBus Compliance ElectricalMechanical EnvironmentalApplicable Documents Handling Precautions Installation Unpacking and InspectionInstallation of M-MODULES MA Configuration Diagram Ethernet Interface Functional Description GeneralModule Interface Power ConversionRear Panel Front Panel Front PanelPage Operating Instructions General Configuring the Ethernet InterfaceIP Address Default gateway address is Port Numbers Default subnet mask is GatewayRecommendation Default setting is Auto-Scan Telnet x.x.x.x Performing the Configuration Wireless Ethernet Wi-Fi Page Table II. Status Code SC Table I. Command SummaryError Handling Communicating with the Carrier and M-MODULESPage Read Data command Write Data commandStarting address + block size * word size Block AccessNumber of bytes = number of blocks * block size * word size 0x50 md as ws ad ai nh nl bs Table III. Register Summary 5 EM405D Configuration/Status RegistersFirmware Version Reset Error & Manufacturer IdentificationDevice Identification Hardware VersionFan Control & Temperature Status Reset & Trigger ControlFollowing values would be invalid Controlling the TriggersFAN and Temperature Control Page Figure A-1 -Pin Dsub Connector Page Table B-1. Ethernet Interface Default Settings Appendix B Wired Ethernet Default SettingsOn Passive Connection True CPU Performance High Page Wireless LAN Settings Table C-1. Wireless Ethernet Configuration Default SettingsCurrent Port Profile TCP Sockets Gpio Page T E S Page Comments Readers Comment FormInstructions