CH Tech EM405D user manual Gpio

Page 43

Table C-1. Wireless Ethernet Configuration Default Settings. (continued)

Advanced Serial Settings

 

Enable Port Logging

False

Enable RTS Toggle

False

Enable RCI over Serial (DSR)

False

Send Socket ID

False

Send data only under any of the following conditions

True

- Send when data is present on the serial line

False

- Send after the following number of idle milliseconds

True - 12 ms

- Send after the following number of bytes

1024

- Close connection after the following number of idle

False

seconds

 

- Close connection when DCD goes low

False

- Close connection when DSR goes low

False

 

 

GPIO

 

General Purpose Input/Output Pins

 

Pin 1

In

Pin 2

In

Pin 3

In

Pin 4

In

Pin 5

In

 

 

Alarms

 

Alarm Notification Settings

 

Enable Alarm Notifications

False

 

 

Alarm Conditions

 

Alarm 1 …Alarm 32

False

 

 

Security

 

Administrator Password

 

Enable Password Authentication

False

 

 

System

 

System Settings

 

Description

blank

Contact

blank

Location

blank

 

 

Simple Network Management Protocol (SNMP) Settings

 

Enable Simple Network Management Protocol (SNMP)

True

- Public community

public

- Private community

private

- Allow SNMP clients to set device settings through SNMP

False

Enable Simple Network Management Protocol (SNMP) traps

False

C-3

Image 43
Contents H E R N E T Copyright 2004 by C&H Technologies, Inc CopyrightDocument Revision Notice Introduction Operating Instructions Table of Contents General DescriptionInstallation Functional DescriptionList of Tables EM405D Ethernet M-Module CarrierKey Features Features and SpecificationsPurpose of Equipment Maximum Ratings SpecificationsBus Compliance ElectricalMechanical EnvironmentalApplicable Documents Handling Precautions Installation Unpacking and InspectionInstallation of M-MODULES MA Configuration Diagram Ethernet Interface Functional Description GeneralModule Interface Power ConversionRear Panel Front Panel Front PanelPage Operating Instructions General Configuring the Ethernet InterfaceIP Address Default gateway address is Port Numbers Default subnet mask is GatewayRecommendation Default setting is Auto-Scan Telnet x.x.x.x Performing the Configuration Wireless Ethernet Wi-Fi Page Table II. Status Code SC Table I. Command SummaryError Handling Communicating with the Carrier and M-MODULESPage Read Data command Write Data commandStarting address + block size * word size Block AccessNumber of bytes = number of blocks * block size * word size 0x50 md as ws ad ai nh nl bs Table III. Register Summary 5 EM405D Configuration/Status RegistersFirmware Version Reset Error & Manufacturer IdentificationDevice Identification Hardware VersionFan Control & Temperature Status Reset & Trigger ControlFollowing values would be invalid Controlling the TriggersFAN and Temperature Control Page Figure A-1 -Pin Dsub Connector Page Table B-1. Ethernet Interface Default Settings Appendix B Wired Ethernet Default SettingsOn Passive Connection True CPU Performance High Page Wireless LAN Settings Table C-1. Wireless Ethernet Configuration Default SettingsCurrent Port Profile TCP Sockets Gpio Page T E S Page Comments Readers Comment FormInstructions