CH Tech EM405D user manual Functional Description General, Ethernet Interface

Page 13

3.0FUNCTIONAL DESCRIPTION

3.1GENERAL

The EM405D provides a mechanical and electrical interface between an Ethernet bus and up to two M-modules. It utilizes an embedded microcontroller to provide buffering and command translation between the Ethernet interface and the M-modules. A simplified functional block diagram is shown in Figure 4.

10/100 BASE-T OR WI-FI

ETHERNET

MICRO

+12VDC IN

OR

HERE

TRG IN

TRG OUT

9-PIN DSUB

POWER

CONVERSION

TRIGGERS

M-MODULE INTERFACE

POSITION B POSITION A

M-MODULE A

M-MODULE B

Figure 4. Functional Block Diagram

3.1.1 Embedded Controller

The embedded controller is implemented using a high-performance microcontroller. The microcontroller executes system firmware that controls the translation between Ethernet and the M-module interface. The system firmware implements a simple command protocol that allows access to the M-modules I/O space, trigger mapping and carrier information and status. It also provides data buffering and fan control.

3.1.2 Ethernet Interface

The Ethernet interface provides the physical and logical connection to the EM405D allowing remote control of the M-modules. The EM405D is available with either wired 10/100 Base-T Ethernet or wireless Ethernet (Wi-Fi). The interface supports the TPC/IP protocol for control of the M-modules. It also supports DHCP, AutoIP, Telnet, HTTP and other standard protocols for device configuration and management.

7

Image 13
Contents H E R N E T Copyright 2004 by C&H Technologies, Inc CopyrightDocument Revision Notice Introduction Installation Table of Contents General DescriptionFunctional Description Operating InstructionsList of Tables EM405D Ethernet M-Module CarrierKey Features Features and SpecificationsPurpose of Equipment Maximum Ratings SpecificationsMechanical ElectricalEnvironmental Bus ComplianceApplicable Documents Handling Precautions Installation Unpacking and InspectionInstallation of M-MODULES MA Configuration Diagram Ethernet Interface Functional Description GeneralModule Interface Power ConversionRear Panel Front Panel Front PanelPage Operating Instructions General Configuring the Ethernet InterfaceIP Address Default gateway address is Port Numbers Default subnet mask is GatewayRecommendation Default setting is Auto-Scan Telnet x.x.x.x Performing the Configuration Wireless Ethernet Wi-Fi Page Error Handling Table I. Command SummaryCommunicating with the Carrier and M-MODULES Table II. Status Code SCPage Read Data command Write Data commandStarting address + block size * word size Block AccessNumber of bytes = number of blocks * block size * word size 0x50 md as ws ad ai nh nl bs Table III. Register Summary 5 EM405D Configuration/Status RegistersDevice Identification Reset Error & Manufacturer IdentificationHardware Version Firmware VersionFan Control & Temperature Status Reset & Trigger ControlFollowing values would be invalid Controlling the TriggersFAN and Temperature Control Page Figure A-1 -Pin Dsub Connector Page Table B-1. Ethernet Interface Default Settings Appendix B Wired Ethernet Default SettingsOn Passive Connection True CPU Performance High Page Wireless LAN Settings Table C-1. Wireless Ethernet Configuration Default SettingsCurrent Port Profile TCP Sockets Gpio Page T E S Page Comments Readers Comment FormInstructions