Delta Electronics RTU-EN01 operation manual Features, Dimension Product Profile LED Indicators

Page 3

Modbus TCP Remote I/O Communication Module RTU-EN01

Introduction

3This operation manual only provides introductory information on electrical specification, installation and wiring.

3RTU-EN01 is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required to open the enclosure) in case danger and damage on the device may occur. DO NOT touch any terminal when the power is switched on.

3Please read this manual carefully and follow the instructions to avoid damage on the product or harm on staff.

Table of Content

1

INTRODUCTION

3

 

1.1

Features

3

 

1.2

Specifications

3

2 PRODUCT PROFILE & OUTLINE

4

 

2.1

Dimension

4

 

2.2

Product Profile

5

 

2.3

LED Indicators

5

 

2.4

RUN/STOP Switch

6

 

2.5

RJ-45 PIN Definition

6

 

2.6

RS-232 PIN Definition

6

 

2.7

RS-485 PIN Definition

6

3

INSTALLATION & WIRING

6

 

3.1

Connecting RTU-EN01 to DVP Slim Series Digital Input/Output Module

6

 

3.2

Installing RTU-EN01 and DVP Slim Series Digital Input/Output Module onto DIN Rail

7

 

3.3

How to Connect RTU-EN01 to Network

7

4 WORD DEVICES & BIT DEVICES IN RTU-EN01

8

 

4.1

Basic Registers (BR)

8

 

4.2

Explanations on BR

9

 

4.3

External Input Contacts (RX)

12

 

4.4

External Output Contacts (RY)

12

 

4.5

Control Register for Extension Modules (RCR)

12

 

4.6

Word Devices & Bit Devices for Timers (T)

13

 

4.7

Word Devices & Bit Devices for Counters (C)

14

 

4.8

Bit Devices for Real-Time Clock (R)

14

5

MODBUS COMMUNICATION

15

 

5.1

Function Codes Supported

15

 

5.2

Exception Codes Supported

15

 

5.3

Device Type & Device Address

16

DVP-PLC Operation Manual

1

Image 3
Contents DVP-0213920-01 RTU-EN01Page Dimension Product Profile LED Indicators FeaturesSetting UP Software Introduction SpecificationsDimension 37.460 LED RJ-45 PIN Definition RUN/STOP SwitchHow to Connect RTU-EN01 to Network Basic Registers BR Word Devices & Bit Devices in RTU-EN01BR#2 Release Date of the Version Explanations on BRBR#0 Model Name BR#1 Firmware VersionBR#7 Number of DI Points BR#5 COM2 Communication SettingsBR#9 Error Code BR#6 AddressBR#23 Number of Analog I/O Modules BR#12 Communication Delay Time msBR#11 Communication Time-out ms BR#13 TCP Connection Idle Time sBR#50 ~ BR#57 RTC Settings RX#0 ~ #255 External Input ContactRY#0 ~ #255 External Output Contact #0 Timer Word Devices & Bit Devices for Timers T#1 ~ #15 Counter 1 ~ #1 ~ #15 Timer 1 ~Word Devices & Bit Devices for Counters C #0 CounterFunction Codes Supported #0 RTC#1 ~ #15 RTC 1 ~ Discrete input CoilHolding register You will see the communication module found „ Recording IP address Basic Settings Static User enters the IP address, subnet mask and gateway Network Settings Setting up Time Server IP Filter „ IF-THEN Smart PLC Setting Timer „ RTC Analog Input/Output Modules Modbus TCP Remote I/O Communication Module RTU-EN01 12 I/O Monitoring Table Setting up Gateway Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Virtual COM Modbus TCP Remote I/O Communication Module RTU-EN01 Security Setting Returning to Default Settings RTU-EN01 DI/DO Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Smart PLC IF-THEN Application Examples DCISoftSmart PLC Timer Smart PLC Counter Smart PLC RTC Virtual COM Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01