Delta Electronics RTU-EN01 operation manual Word Devices & Bit Devices for Timers T, #0 Timer

Page 15

Modbus TCP Remote I/O Communication Module RTU-EN01

RCR#

Attribute

 

Content

Explanation

Default

Latched

200 ~ 249

R/W

The 5th

analog I/O

Control register for the 5th analog I/O

--

NO

module

 

module

 

 

 

 

 

250 ~ 299

R/W

The 6th

analog I/O

Control register for the 6th analog I/O

--

NO

module

 

module

 

 

 

 

 

300 ~ 349

R/W

The 7th

analog I/O

Control register for the 7th analog I/O

--

NO

module

 

module

 

 

 

 

 

350 ~ 399

R/W

The 8th

analog I/O

Control register for the 8th analog I/O

--

NO

module

 

module

 

 

 

 

 

Symbol “R” refers to ready only; “R/W” refers to read and write.

RCR#0 ~ #399: Control Register for Right-Side Analog I/O Modules

Explanations:

By reading/writing RCR in RTU-EN01, you are able to store or retrieve the data in the control register (CR) inside the analog input/output module.

Example: RCR#0 corresponds to CR#0 in the 1st analog I/O module. RCR#260 corresponds to CR#10 in the 6th analog I/O module. Extension module closest to RTU-EN01 is regarded the 1st module.

4.6 Word Devices & Bit Devices for Timers (T)

T#

Attribute

Register/coil name

Explanation

0

R/W

Timer 0

Timer

 

 

 

 

1

R/W

Timer 1

Timer

 

 

 

 

2

R/W

Timer 2

Timer

 

 

 

 

3

R/W

Timer 3

Timer

 

 

 

 

4

R/W

Timer 4

Timer

 

 

 

 

5

R/W

Timer 5

Timer

 

 

 

 

6

R/W

Timer 6

Timer

 

 

 

 

7

R/W

Timer 7

Timer

 

 

 

 

8

R/W

Timer 8

Timer

 

 

 

 

9

R/W

Timer 9

Timer

 

 

 

 

10

R/W

Timer 10

Timer

 

 

 

 

11

R/W

Timer 11

Timer

 

 

 

 

12

R/W

Timer 12

Timer

 

 

 

 

13

R/W

Timer 13

Timer

 

 

 

 

14

R/W

Timer 14

Timer

 

 

 

 

15

R/W

Timer 15

Timer

 

 

 

 

Symbol “R” refers to ready only; “R/W” refers to read and write.

Default 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF 0/OFF

Latched

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

T#0: Timer 0

Explanations:

When the timer is enabled, it will start to time according to the settings. When the timing reaches the target, the bit device T0 will be ON. When the bit device is reset, the word device will be reset to 0 as well.

DVP-PLC Operation Manual

13

Image 15
Contents DVP-0213920-01 RTU-EN01Page Dimension Product Profile LED Indicators FeaturesSetting UP Software Introduction SpecificationsDimension 37.460 LED RJ-45 PIN Definition RUN/STOP SwitchHow to Connect RTU-EN01 to Network Basic Registers BR Word Devices & Bit Devices in RTU-EN01BR#2 Release Date of the Version Explanations on BRBR#0 Model Name BR#1 Firmware VersionBR#7 Number of DI Points BR#5 COM2 Communication SettingsBR#9 Error Code BR#6 AddressBR#23 Number of Analog I/O Modules BR#12 Communication Delay Time msBR#11 Communication Time-out ms BR#13 TCP Connection Idle Time sBR#50 ~ BR#57 RTC Settings RX#0 ~ #255 External Input ContactRY#0 ~ #255 External Output Contact #0 Timer Word Devices & Bit Devices for Timers T#1 ~ #15 Counter 1 ~ #1 ~ #15 Timer 1 ~Word Devices & Bit Devices for Counters C #0 CounterFunction Codes Supported #0 RTC#1 ~ #15 RTC 1 ~ Discrete input CoilHolding register You will see the communication module found „ Recording IP address Basic Settings Static User enters the IP address, subnet mask and gateway Network Settings Setting up Time Server IP Filter „ IF-THEN Smart PLC Setting Timer „ RTC Analog Input/Output Modules Modbus TCP Remote I/O Communication Module RTU-EN01 12 I/O Monitoring Table Setting up Gateway Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Virtual COM Modbus TCP Remote I/O Communication Module RTU-EN01 Security Setting Returning to Default Settings RTU-EN01 DI/DO Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Smart PLC IF-THEN Application Examples DCISoftSmart PLC Timer Smart PLC Counter Smart PLC RTC Virtual COM Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01