Modbus TCP Remote I/O Communication Module RTU-EN01

2.2 Product Profile

1.

POWER indicator

12.

RS-485 communication port

2.

RUN indicator

13.

Extension module positioning hole

 

 

 

 

3.

BAT.LOW indicator

14.

Nameplate

 

 

 

 

4.

RUN/STOP switch

15.

Extension port

 

 

 

 

5.

RS-232 indicator

16.

DIN rail (35mm)

 

 

 

 

6.

RS-485 indicator

17.

Extension module fixing clip

 

 

 

 

7.

LINK/ACK indicator

18.

DIN rail clip

 

 

 

 

8.

SPEED indicator

19.

Power supply port

 

 

 

 

9.

Digital display

20.

3P terminal block (standard accessory)

 

 

 

10.

Ethernet communication port

21. Power supply connection cable (standard

 

 

 

accessory)

11.

RS-232 communication port

 

 

 

 

 

 

 

2.3 LED Indicators

LED

Color

Function

POWER

Green

Power supply indication

 

 

 

RUN

Green

RUN/STOP indication

 

 

 

BAT.LOW

Red

Battery in low power indication

 

 

 

RS-232

Yellow

Displaying communication status of RS-232 port

 

 

 

RS-485

Yellow

Displaying communication status of RS-485 port

 

 

 

LINK/ACT

Green

Displaying the status of network

 

 

 

SPEED

Yellow

Displaying the speed of network connection

 

 

 

DVP-PLC Operation Manual

5

Image 7
Contents DVP-0213920-01 RTU-EN01Page Dimension Product Profile LED Indicators FeaturesSetting UP Software Introduction SpecificationsDimension 37.460 LED RJ-45 PIN Definition RUN/STOP SwitchHow to Connect RTU-EN01 to Network Basic Registers BR Word Devices & Bit Devices in RTU-EN01BR#2 Release Date of the Version Explanations on BRBR#0 Model Name BR#1 Firmware VersionBR#7 Number of DI Points BR#5 COM2 Communication SettingsBR#9 Error Code BR#6 AddressBR#23 Number of Analog I/O Modules BR#12 Communication Delay Time msBR#11 Communication Time-out ms BR#13 TCP Connection Idle Time sRX#0 ~ #255 External Input Contact BR#50 ~ BR#57 RTC SettingsRY#0 ~ #255 External Output Contact #0 Timer Word Devices & Bit Devices for Timers T#1 ~ #15 Counter 1 ~ #1 ~ #15 Timer 1 ~Word Devices & Bit Devices for Counters C #0 Counter#0 RTC Function Codes Supported#1 ~ #15 RTC 1 ~ Coil Discrete inputHolding register You will see the communication module found „ Recording IP address Basic Settings Static User enters the IP address, subnet mask and gateway Network Settings Setting up Time Server IP Filter „ IF-THEN Smart PLC Setting Timer „ RTC Analog Input/Output Modules Modbus TCP Remote I/O Communication Module RTU-EN01 12 I/O Monitoring Table Setting up Gateway Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Virtual COM Modbus TCP Remote I/O Communication Module RTU-EN01 Security Setting Returning to Default Settings RTU-EN01 DI/DO Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Smart PLC IF-THEN Application Examples DCISoftSmart PLC Timer Smart PLC Counter Smart PLC RTC Virtual COM Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01