Sharp AL-1215 Using the Scanner Mode, Using the Button Manager, Setting up the Button Manager

Page 36

USING THE SCANNER MODE

The scanner driver for this unit includes an STI (Still image) driver and WIA (Windows Image Acquisition) driver. You can install software that supports the STI driver and WIA driver to enable scanning using the operation panel of the unit.

For problems with the scanner function, see the online manual or the help file for the driver.

Using the Button Manager

Setting up the Button Manager

The Button Manager accessory software supports the STI driver and WIA driver. Setup that is required in Windows to use the Button Manager is explained in the following.

Windows XP

1

2

3

4

Click the "start" button, select "Control Panel" and click "Printers and Other Hardware", and then click "Scanners and Cameras" in the start menu. Right click the "SHARP AL-xxxx" (where xxxx is the model name of your unit) icon and click "Properties" in the menu that appears.

In the "Properties" screen, click the "Events" tab.

Click the "Select an event" button and select "ScanMenu SC1" from the pull-down menu. Select "Button Manager (SHARP Personal MFP series)" in "Start this program" and click "Apply".

Repeat Step3 to set "ScanMenu SC2" through "ScanMenu SC6" .

Click the "Select an event" button and select "ScanMenu SC2" from the pull- down menu. Select "Button Manager (SHARP Personal MFP series)" in "Start this program" and click "Apply". Do the same for each ScanMenu through "ScanMenu SC6".

When the settings have been completed, click the "OK" button to close the screen. When the settings have been completed in Windows, start the Button Manager. Adjust detailed settings and then scan an image from the unit. For the procedures for starting Button Manager and adjusting settings, see "Scan Button Destination Setting Dialog Box" (p.36).

34

Image 36
Contents AL-1215 AL-1530CS AL-1540CS AL-1551CS For Your Protection Important points when selecting an installation site Do not install your unit in areas that areSafety precautions Trademark acknowledgementsContents Using the Manuals Online manual AL-1530CS, AL-1540CS, AL-1551CSConventions used in this manual and online manual Part Names SPF/RSPF AL-1540CS/1551CS Original coverAL-1215/1530CS Paper tray Single bypass AL-1215/1530CS/ 1540CS InterfaceOriginal to copy key and indicators AL-1551CS Operation PanelSetting UP the Unit Setup ProcedureChecking Packed Components and Accessories Preparing the Unit for InstallationRelease the scan head locking switch LockUnlockInstalling the TD Cartridge Page Power on About the scan headPower off methods Initial settings of operation panelAL-1551CS only Type of paper Type of media Size Weight Feeding PaperLoading the Paper Tray Gently push the paper tray back into the unit Multi-bypass tray AL-1551CS Open the multi-bypass tray and extend the trayUsing copy mode Using printer modeSingle bypass AL-1215/AL-1530CS/AL-1540CS Press the tray select key to select the multi-bypass traySoftware for the Sharp Personal MFP Series MFP driverSharpdesk Button ManagerBefore Installation Hardware and Software RequirementsMFP Driver Button Installing the Software Flow of installationInstalling onto Windows XP USB/parallel interface Operating Interface Reference pages for how to installDouble-click the setup icon Button Manager installer will start Begin installation of the scanner driver Begin installation of the printer driverInstalling onto Windows 98/Me/2000 USB interface Copying files for MFP driver installation Click the Close button when Windows 95/NT Establish the printer settings and click the Next button You have completed the installation of all the software Indicators on the Operation Panel Start indicatorOnline indicator Power save indicatorUsing the Printer Mode Opening the printer driver from the start menuHow to print Using the Scanner Mode Using the Button ManagerSetting up the Button Manager Windows 98/Me/2000 Properties screen, clickEvents tab Scan Button Destination Setting Dialog Box Flow of the Button Manager setting Scanner AL Event Using the Scanner key to begin scanning Press the Scanner keyPress the right copy quantity key to Application Application launched NumberOpening the scanner driver and scanning from your computer Press the start KeySelect Sharp Personal MFP Series, and click the Select Scanning with the Scanner and Camera Wizard in Windows XP Select a name, format, and folder for the scanned imageClick Finish in the screen that appears HOW to USE the Online Manual Installing Acrobat ReaderClick the to read the online manual Using Other Installed Drivers Connecting the Interface Cable Connecting the USB interface cableConnecting the parallel interface cable Obtain a shielded USB interface cableSelect the copy settings If you are using the single bypassCopy Flow Place the originalOriginal Placement Using the original tableAbout interrupt copying Using the SPF/RSPF Stream feeding modeOriginal feeder tray Exposure ADJUSTMENT/PHOTO Copying Exposure adjustmentPhoto mode SET the Copy QuantityAutomatic exposure adjustment REDUCTION/ENLARGEMENT/ZOOM Set the reduction/enlargement ratioTo select a zoom ratio About the Special Functions of AL-1551CS Two sided copyingMaking two-sided copies Selecting the tray Press the tray select keyToner Save Mode Description of Special FunctionsUser Programs Program Mode Parameters Displaying Total Number of CopiesTD Cartridge Replacement Gently pull the TD cartridge outWhile pressing the lock release Button Drum Cartridge Replacement Gently pull the cartridge out. DisposeCleaning the Unit CabinetOriginal table and the back side of the original cover/SPF Transfer charger Troubleshooting the Unit TroubleshootingStatus Indicators Indication Cause and remedyMisfeed Removal Paper feed area. p.66Misfeed in the paper feed area. p.64 Misfeed in the fusing area Misfeed in the paper feed areaLower the fusing unit release lever Misfeed in the transport areaOpen the front cover Rotate the feeding roller Direction of the arrowMisfeed in the lower paper feed area AL-1551CS Misfeed in the SPF/RSPFOpen the lower side cover under the multi-bypass AL-1551CS Specifications AppendixSharp GDI About Supplies and Options Supply listInterface cable Parallel interface cableMoving and Storing the Unit Moving instructionsProper storage Store the supplies in a location that isIndex Rspf SPFMFP driver Index by Purpose Software License Limited Warranty on Media Material Safety Data Sheet Hazards Identification Exposure Control / Personal Protection Ecological Information Data Revised Jun.28.2002 Data Issued Msds NO. F-30831 Specific hazards None Stability DOT USA For users in the USA Sharp Electronics Corporation