MATERIAL SAFETY DATA SHEET

Page: 4/4

Data Revised: Jun.28.2002

Data Issued: Jun. 1.1998 MSDS NO. F-00831

Chronic Effect :In a study in rats of chronic inhalation exposure to a typical toner, a mild to moderate degree of lung fibrosis was observed in 92% of the rats in the high concentration (16mg/m3) exposure group, and a minimal to mild degree of fibrosis was noted in 22% of the animals in the middle (4mg/m3) exposure group, but no pulmonary change was reported in the lowest (1mg/m3) exposure group, the most relevant level to potential human exposures.

12.ECOLOGICAL INFORMATION

No data are available.

13.DISPOSAL CONSIDERATION

Waste from residues :Waste material may be dumped or incinerated under conditions

which meet all federal, state and local environmental regulations. Contaminated Packaging :Waste may be disposed or incinerated under conditions which meet

all federal, state and local environmental regulations.

14. TRANSPORT INFORMATION

UN Classification:None

Not classified as hazardous for transport.

15.REGULATORY INFORMATION

US Information

TSCA (Toxic Substances Control Act) :

All chemical substances in this product comply with all applicable rules or order under TSCA. SARA (Superfund Amendments and Reauthorization Act) Title III

302 Extreme Hazardous Substance :None

311/312 Hazard Classification

:None

EU Information

 

1999/45/EC and 67/548/EEC

 

Symbol & Indication

:Not required

R-Phrase

:Not required

76/769/EEC :All chemical substances in this product comply with all applicable rules or order

under 76/769/EEC.

 

16. OTHER INFORMATION

NFPA Rating (USA)

:Health=1 Flammability=1 Reactivity=0

WHMIS Legislation (Canada)

:This product is not a controlled product.

List of R phrases

:R11 : Highly flammable

References

 

IARC (1996) :IARC monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Humans, Vol. 65, Printing Process And Printing Inks, Carbon Black and Some Nitro Compounds, Lyon, pp.149-261

H.Muhle, B.Bellmann, O.Creutzenberg, C.Dasenbrock, H.Ernst, R.Kilpper, J.C.MacKenzie, P.Morrow, U.Mohr,

S.Takenaka, and R.Mermelstein (1991) Pulmonary Response to Toner upon Chronic Inhalation Exposure in Rats.

Fundamental and Applied Toxicology 17, pp.280-299.

The information on this data sheet represents our current data and best opinion as to the proper use in handling of this product under normal conditions. However, all materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we do not guarantee that these are the only hazards which exist.

Image 82
Contents AL-1215 AL-1530CS AL-1540CS AL-1551CS For Your Protection Important points when selecting an installation site Do not install your unit in areas that areSafety precautions Trademark acknowledgementsContents Online manual AL-1530CS, AL-1540CS, AL-1551CS Using the ManualsConventions used in this manual and online manual AL-1215/1530CS Part NamesSPF/RSPF AL-1540CS/1551CS Original cover Paper tray Single bypass AL-1215/1530CS/ 1540CS InterfaceOriginal to copy key and indicators AL-1551CS Operation PanelSetting UP the Unit Setup ProcedureChecking Packed Components and Accessories Preparing the Unit for InstallationRelease the scan head locking switch LockUnlockInstalling the TD Cartridge Page Power on About the scan headInitial settings of operation panel Power off methodsAL-1551CS only Type of paper Type of media Size Weight Feeding PaperLoading the Paper Tray Gently push the paper tray back into the unit Multi-bypass tray AL-1551CS Open the multi-bypass tray and extend the traySingle bypass AL-1215/AL-1530CS/AL-1540CS Using copy modeUsing printer mode Press the tray select key to select the multi-bypass traySharpdesk Software for the Sharp Personal MFP SeriesMFP driver Button ManagerHardware and Software Requirements Before InstallationMFP Driver Button Installing onto Windows XP USB/parallel interface Installing the SoftwareFlow of installation Operating Interface Reference pages for how to installDouble-click the setup icon Button Manager installer will start Begin installation of the scanner driver Begin installation of the printer driverInstalling onto Windows 98/Me/2000 USB interface Copying files for MFP driver installation Click the Close button when Windows 95/NT Establish the printer settings and click the Next button You have completed the installation of all the software Online indicator Indicators on the Operation PanelStart indicator Power save indicatorUsing the Printer Mode Opening the printer driver from the start menuHow to print Using the Button Manager Using the Scanner ModeSetting up the Button Manager Properties screen, click Windows 98/Me/2000Events tab Scan Button Destination Setting Dialog Box Flow of the Button Manager setting Scanner AL Event Press the right copy quantity key to Using the Scanner key to begin scanningPress the Scanner key Application Application launched NumberOpening the scanner driver and scanning from your computer Press the start KeySelect Sharp Personal MFP Series, and click the Select Select a name, format, and folder for the scanned image Scanning with the Scanner and Camera Wizard in Windows XPClick Finish in the screen that appears Installing Acrobat Reader HOW to USE the Online ManualClick the to read the online manual Using Other Installed Drivers Connecting the parallel interface cable Connecting the Interface CableConnecting the USB interface cable Obtain a shielded USB interface cableCopy Flow Select the copy settingsIf you are using the single bypass Place the originalUsing the original table Original PlacementAbout interrupt copying Stream feeding mode Using the SPF/RSPFOriginal feeder tray Photo mode Exposure ADJUSTMENT/PHOTO CopyingExposure adjustment SET the Copy QuantityAutomatic exposure adjustment Set the reduction/enlargement ratio REDUCTION/ENLARGEMENT/ZOOMTo select a zoom ratio Two sided copying About the Special Functions of AL-1551CSMaking two-sided copies Selecting the tray Press the tray select keyToner Save Mode Description of Special FunctionsUser Programs Program Mode Parameters Displaying Total Number of CopiesGently pull the TD cartridge out TD Cartridge ReplacementWhile pressing the lock release Button Drum Cartridge Replacement Gently pull the cartridge out. DisposeCabinet Cleaning the UnitOriginal table and the back side of the original cover/SPF Transfer charger Troubleshooting the Unit TroubleshootingStatus Indicators Indication Cause and remedyPaper feed area. p.66 Misfeed RemovalMisfeed in the paper feed area. p.64 Misfeed in the fusing area Misfeed in the paper feed areaOpen the front cover Lower the fusing unit release leverMisfeed in the transport area Rotate the feeding roller Direction of the arrowMisfeed in the SPF/RSPF Misfeed in the lower paper feed area AL-1551CSOpen the lower side cover under the multi-bypass AL-1551CS Specifications AppendixSharp GDI Interface cable About Supplies and OptionsSupply list Parallel interface cableProper storage Moving and Storing the UnitMoving instructions Store the supplies in a location that isIndex Rspf SPFMFP driver Index by Purpose Software License Limited Warranty on Media Material Safety Data Sheet Hazards Identification Exposure Control / Personal Protection Ecological Information Data Revised Jun.28.2002 Data Issued Msds NO. F-30831 Specific hazards None Stability DOT USA For users in the USA Sharp Electronics Corporation