TANDBERG D1320202 manual Tandberg GW

Page 17

TANDBERG GW

Data port Command Interface User Guide

LinkSet [1 .. 2] Link [1 .. 2] Timeslot: <1 .. 31>

LinkSet [1 .. 2] Link [1 .. 2] SLC: <0 .. 15>

Trunk [1 .. 4] Mode: <On/Off>

Trunk [1 .. 4] DPC: <0 .. 16383>

Trunk [1 .. 4] CircuitIdentificationCode: <0 .. 16383>

Route [1 .. 8] DPC: <0 .. 16383>

Route [1 .. 8] Priority: <1 .. 4>

Route [1 .. 8] LinkSet: <Off/1/2>

---

sub-commands:

OPC: A number between 0-214, which uniquely identifies a signaling point, in this case the 3G Gateway, within a telephone network. This number consists of three parts, i.e. a network, cluster and member number, and will be provided by the network operator.

NetworkIndicator:,A two bit data field within the Service Information Octet of the Message Signal Unit that permits discrimination between national and international messages.

Law: audio standard: Either ALAW or ULAW. An a-law algorithm is a standard companding, i.e. compressing and expanding, algorithm, used in European digital communication systems to optimize, i.e. modify, the dynamic range of an analog signal for digitizing. The µ- law algorithm is similar to a-law and used in North American and Japanese systems.

LinkSet Mode: Enable or disable linksets.

LinkSet DPC: Uniquely identifies the destination signaling point of the link. This can differ from the DPC of the trunk, e.g. the DPC of a Signaling Transfer Point (STP), see example 2 below.

LinkSet Link Mode: Enable a link in a link set.

LinkSet Link Trunk: Number of the trunk (1 - 4) in which a time slot is reserved for signaling.

LinkSet Link Timeslot: Number of the time slot, within aforementioned trunk, reserved for signaling.

LinkSet Link SLC: A Signaling Link Code is a unique link number provided by the network operator to identify a link.

Trunk Mode: Enable or disable a trunk.

Trunk DPC: Uniquely identifies the destination signaling point of the trunk. It will be provided by the network operator.

Trunk CircuitIdentificationCode: The Circuit Identification Code is a unique identifier for a data time slot in a cable (trunk). In this case the CIC acts as base address and can be defined for each SS7 trunk and sets the first time-slot number of the respective SS7 trunk.

Route DPC: Unique identifier indicating the destination signaling point of a trunk.

Route Priority: Priority level of the route to the destination signaling point. Fail-over signaling paths will be followed according to this priority.

Route LinkSet: Indicates the link to the destination signaling point according to the above mentioned priority setting.

For more details on the sub-commands please read the chapter about SS7

17

Image 17
Contents D1320202 Tandberg 3G GWTable of Contents Introduction Hardware and Cabling Tandberg GWTroubleshooting Connecting to the Data port Command Interface using Telnet Command types Command formatIntroduction Xconf H323Gatekeeper ?Xconf telnet mode CommandsXconf telnet mode on Command Description H323Gatekeeper System Configuration CommandsH323CallSetup H323CallSetup Mode Direct/GatekeeperIsdn EthernetEthernet speed Snmp HttpsHttp Telnet SSHTandberg GW Command Description Gateway General GW CommandsNTP SIP Tandberg GW Example of SS7 feedback Tandberg GW VideoPortal Mode On/Off or System 1 . IP Address IPAddrTemperatureCelcius System Status CommandsTemperatureFahrenheit PRIDNS URL Status Address PortAddress Protocol PRI BRIFeedback Feedback 1GatewayCall StatusSystemLoad Status Address Port Last Update Last CorrectionSystemLoad Call 1 CallSpecial Commands Debug CommandsParameters Error Result parametersExpression 1 . S 0, 256 XPath expression OK Result parametersParameters ServiceEntryNumberr Example Delete Service nr ServiceEntryDeleteServiceEntrySwap OptionKeyDeleteXhistory ? ExamplesXhistory Tandberg GW Index Commands