2.Connecting to the Data port Command Interface through the RS-232 port.

The RS-232 port is a 9-pin, female, D-sub connector located on the front of the GW. The port is configured as a DCE (Data Communications Equipment). The RS-232 port is default set to 115200 baud, 8 data bits, none parity and 1 stop bit from factory. The RS-232 port is also referred to as the Data port.

2.1.Hardware and Cabling

The pin outs for the RS-232 are defined in the following table (the DTE, Data Terminal Equipment, could be a PC or other device capable of serial communication).

Pin no

Signal

Description

Direction

1

CD

Carrier detect

To DTE

2

RD

Receive data

To DTE

3

TD

Transmit data

From DTE

4

DTR

Data terminal ready

From DTE

5

 

Ground

 

6

DSR

Data set ready

To DTE

7

RTS

Ready to send

From DTE

8

CTS

Clear to send

To DTE

9

RI

Ring indicator

To DTE

NOTE! A straight through cable should be used between the TANDBERG GW’s RS-232 port and the DTE.

The figure below illustrates the recommended cable-wiring scheme for connecting the GW to a PC through RS-232.

TANDBERG GW

PC

 

 

DCE, 9 pin

DTE, 9 pin

 

1

CD

1

CD

2

RD

2

RD

3

TD

3

TD

4

DTR

4

DTR

5

GND

5

GND

6

DSR

6

DSR

7

RTS

7

RTS

8

CTS

8

CTS

9

RI

9

RI

 

 

 

 

DTR and RTS are ignored. DSR, CD, and CTS are always asserted, while RI is not used.

4

Image 4
Contents Tandberg 3G GW D1320202Table of Contents Introduction Tandberg GW Hardware and CablingTroubleshooting Connecting to the Data port Command Interface using Telnet Command format Command typesIntroduction Xconf H323Gatekeeper ?Xconf telnet mode on CommandsXconf telnet mode System Configuration Commands Command Description H323GatekeeperH323CallSetup H323CallSetup Mode Direct/GatekeeperEthernet speed EthernetIsdn Http HttpsSnmp SSH TelnetTandberg GW General GW Commands Command Description GatewayNTP SIP Tandberg GW Example of SS7 feedback Tandberg GW Mode On/Off or System 1 . IP Address IPAddr VideoPortalSystem Status Commands TemperatureCelciusTemperatureFahrenheit PRIDNS Address Protocol Status Address PortURL BRI PRIFeedback 1 FeedbackGatewayCall StatusStatus Address Port Last Update Last Correction SystemLoadSystemLoad Call 1 CallDebug Commands Special CommandsError Result parameters ParametersExpression 1 . S 0, 256 XPath expression OK Result parametersServiceEntryDelete Parameters ServiceEntryNumberr Example Delete Service nrServiceEntrySwap OptionKeyDeleteXhistory ExamplesXhistory ? Tandberg GW Index Commands