TANDBERG T1 manual Add the system to the network, Verify your settings, Time zone settings

Page 14

T1

ContentsIntroduction

Administrator Guide

 

Gettinget ing startstarted

About the menus

About the settings

Settings Library

Cameras

Appendices

Contact us

 

 

 

 

 

 

 

 

4

Add the system to the network

Your service provider should have provided you with the information you

need to get on-line.

For H323 type of communication, this will include such things as system name, H323 alias, gatekeeper address, etc. For SIP type of communication, similar type of information will be supplied.

For networks administrated through TMS (TANDBERG Management Suite), your TMS administrator will be able to assist you when configuring.

The H323 and SIP settings are configured from the Administrator Settings menu:

Navigate to Settings > Administrator Settings > Advanced Settings.

Expand the items in need of modification and enter the information supplied by your service provider.

5

Verify your settings

We strongly recommend that you verify the settings by inspecting the System

Information list.

You do this by accessing the System Information in the same way as you did when you verified you IP address setting.

Go to System Information to verify the settings:

1.Navigate to Settings > System Information

2.Verify the previous configurations. For example, if you successfully registered to a SIP server the Status will show Registered. If the registration failed the Status will show Not registered.

3.Press Home (   ) to exit.

Time zone settings

6

Verify the date and time to see if the time zone settings need to be adjusted. The

date and time is located in the upper right corner on screen.

 

Go to Time settings to set the NTP (date and time) settings:

 

1.

Navigate to Settings > Administrator Settings > Time

 

2.

You may need to consult the NTP Time Zone expression list to find the

 

 

right expression. Go to the Appendices section and the NTP Time Zone

 

 

expressions to see a complete overview.

 

3.

Enter the time zone expression for where the system is located. The default

 

 

value is Etc/UTC.

 

 

NOTE: Spelling correctly is important when entering the NTP Time Zone

 

 

expression

 

4.

Press Save to save the changes, or Cancel to leave without saving.

 

5.

Press Home (   ) to exit.

D14274.01—NOVEMBER 2008

14

Image 14
Contents Tandberg T1 NovemberTable of Contents What’s in this guide?This chapter IntroductionChapter Tandberg T1 at a glance Disclaimer Intellectual Property RightsTrademark Patent InformationSafety Instructions Water and MoistureEnvironmental Issues TANDBERG’s Environmental PolicyGetting started System overview Cable configurations LANUsing the Remote Control BatteriesUsing the Remote Control, Call KEYIf you need to set a static IP address Verify IP address settingsTurn on the system Add the system to the network Verify your settingsTime zone settings About the menus About the menus Settings The Settings menuAdministrator settings menu Home The Home menuSettings menu Explaining the administrator settingsAdministrator settings IP Settings menuAdvanced configuration menu SearchAdministrator Settings Library SIPAdvanced configuration menu Audio settingsAudio Input Line 1. Level Audio Output Hdmi 1, 3 Mode On/OffAudio Output Line 1. Mode On/Off Audio Input Line 1. Channel Left/Right/MonoCamera settings Conference settings Do not disturb setting Network settings Network services settings NetworkServices Snmp SystemContact S 0 NetworkServices Snmp Mode Off/ReadOnly/ReadWriteNetworkServices Snmp CommunityName S 0 NetworkServices Snmp SystemLocation S 0Serial port settings Phone book server settingsProvisioning settings SIP Profile settings Standby settingsSystem unit settings Time zone settingVideo Input Source 1. CameraControl Mode On/Off Video OSD Mode On/OffVideo Input Source 2 Connector HDMI/HDSDI/YPbPr Video Input Source 1 Connector HDMI/HDSDI/YPbPrExample Video Output DVI 2 Resolution Video Output Composite 5 Resolution PAL/NTSCExample Video Output Hdmi 1 Resolution Example Video Output Composite 5 Resolution NtscCameras Kensington lock PrecisionHD 1080p cameraHdmi and HD-SDI Cascaded camerasConnecting the camera Tandberg T1Tandberg TRC5 Using Best viewBest view-Face recognition Line voltage frequency DIP switch settings for video output formatsVideo output formats Cameras in daisy chain Appendices Tandberg DnamRoom equipment General room guidelinesPhysical conditions Environmental considerationsBest audio quality to all participants Audio qualityNatural communication Making eye contactGeneral recommendations for the room layout Guidelines for the telepresence room setupAdjust the camera view Distance between the table and the video systemSharing a PC presentation Shows the PC presentation and the participantsGuidelines for the high end meeting room setup Camera viewAdministrator Guide Tandberg Remote Control TRC5 ArrowsAPI commands Configure the video inputsAdministrator settings Video Input MatrixSoftware upgrade Software upgrade procedureUpload certificates Certificates upload procedureHow to upload the certificate XML files ConfigurationCommand View XML filesLog files Debug log filesDnam Loudspeaker Cabinet Dnam AmplifierNTP Time Zone expressions NTP Time Zone expressions, NZ-CHAT GMT+0GMT0 CETMedia capabilities supported in SIP Supported RFCs in SIPCurrent RFCs and drafts supported in SIP CE Declaration for Telepresence T1 China RoHS table Left side view Tandberg T1 dimensionsFront view Top viewPrecisionHD 1080p camera dimensions PAL/NTSC Technical specificationsUnit Delivered Complete with HTTP, Https TCP/IP DhcpGpio Headquarters European Headquarters Tandberg