The video output format for the camera is set by DIP switches. The DIP switches are found on the bottom side of the camera.

The default setting is Auto. When using HDMI, the video output format is automatically detected. See the table to the right.

Maximum resolution for HDMI is 1080p60. Maximum resolution for HD-SDI is 1080p30.

Line voltage frequency

The camera will automatically detect the line voltage frequency when it is 50 or 60 Hz. You may set the video output format to a specific value (use the DIP switches) to override the auto frequency detection, if a different line voltage frequency is an issue.

1

0

The DIP switch

Bottom side of the TANDBERG PrecisionHD 1080p camera

DIP Switch table for video formats

1

2

3

4

5

HDMI

 

HD-SDI

 

 

 

 

 

 

 

 

0

0

0

0

0

 

Auto

 

 

 

 

 

 

 

 

0

0

0

0

1

1920x1080p25

 

1920x1080p25

 

 

 

 

 

 

 

 

0

0

0

1

0

1920x1080p30

 

1920x1080p30

 

 

 

 

 

 

 

 

0

0

0

1

1

1920x1080p50

 

1280x720p50

 

 

 

 

 

 

 

 

0

0

1

0

0

1920x1080p60

 

1280x720p60

 

 

 

 

 

 

 

 

0

0

1

0

1

1280x720p25

 

1280x720p25

 

 

 

 

 

 

 

 

0

0

1

1

0

1280x720p30

 

1280x720p30

 

 

 

 

 

 

 

 

0

0

1

1

1

1280x720p50

 

1280x720p50

 

 

 

 

 

 

 

 

0

1

0

0

0

1280x720p60

 

1280x720p60

 

 

 

 

 

 

 

0

1

0

0

1

Software control

 

 

 

 

 

 

 

 

The table shows the different settings available for the HDMI and the HD-SDI outputs.

Auto: Camera negotiates format over HDMI. HD-SDI tracks HDMI and defaults to 1080p30 in absence of HDMI sync.

Software: For more on the Software control setting, read about video mode selections in the TANDBERG PrecisionHD 1080p User Guide.

D14274.01—NOVEMBER 2008

38

Image 38
Contents Tandberg T1 NovemberTable of Contents What’s in this guide?This chapter IntroductionChapter Tandberg T1 at a glance Disclaimer Intellectual Property RightsTrademark Patent InformationSafety Instructions Water and MoistureEnvironmental Issues TANDBERG’s Environmental PolicyGetting started System overview Cable configurations LANUsing the Remote Control BatteriesUsing the Remote Control, Call KEYIf you need to set a static IP address Verify IP address settingsTurn on the system Add the system to the network Verify your settingsTime zone settings About the menus About the menus Settings The Settings menuAdministrator settings menu Home The Home menuSettings menu Explaining the administrator settingsAdministrator settings IP Settings menuAdvanced configuration menu SearchAdministrator Settings Library SIPAdvanced configuration menu Audio settingsAudio Input Line 1. Level Audio Output Hdmi 1, 3 Mode On/OffAudio Output Line 1. Mode On/Off Audio Input Line 1. Channel Left/Right/MonoCamera settings Conference settings Do not disturb setting Network settings Network services settings NetworkServices Snmp SystemContact S 0 NetworkServices Snmp Mode Off/ReadOnly/ReadWriteNetworkServices Snmp CommunityName S 0 NetworkServices Snmp SystemLocation S 0Serial port settings Phone book server settingsProvisioning settings SIP Profile settings Standby settingsSystem unit settings Time zone settingVideo Input Source 1. CameraControl Mode On/Off Video OSD Mode On/OffVideo Input Source 2 Connector HDMI/HDSDI/YPbPr Video Input Source 1 Connector HDMI/HDSDI/YPbPrExample Video Output DVI 2 Resolution Video Output Composite 5 Resolution PAL/NTSCExample Video Output Hdmi 1 Resolution Example Video Output Composite 5 Resolution NtscCameras Kensington lock PrecisionHD 1080p cameraHdmi and HD-SDI Cascaded camerasConnecting the camera Tandberg T1Tandberg TRC5 Using Best viewBest view-Face recognition Line voltage frequency DIP switch settings for video output formatsVideo output formats Cameras in daisy chain Appendices Tandberg DnamRoom equipment General room guidelinesPhysical conditions Environmental considerationsBest audio quality to all participants Audio qualityNatural communication Making eye contactGeneral recommendations for the room layout Guidelines for the telepresence room setupAdjust the camera view Distance between the table and the video systemSharing a PC presentation Shows the PC presentation and the participantsGuidelines for the high end meeting room setup Camera viewAdministrator Guide Tandberg Remote Control TRC5 ArrowsAPI commands Configure the video inputsAdministrator settings Video Input MatrixSoftware upgrade Software upgrade procedureUpload certificates Certificates upload procedureHow to upload the certificate XML files ConfigurationCommand View XML filesLog files Debug log filesDnam Loudspeaker Cabinet Dnam AmplifierNTP Time Zone expressions NTP Time Zone expressions, NZ-CHAT GMT+0GMT0 CETMedia capabilities supported in SIP Supported RFCs in SIPCurrent RFCs and drafts supported in SIP CE Declaration for Telepresence T1 China RoHS table Left side view Tandberg T1 dimensionsFront view Top viewPrecisionHD 1080p camera dimensions PAL/NTSC Technical specificationsUnit Delivered Complete with HTTP, Https TCP/IP DhcpGpio Headquarters European Headquarters Tandberg