The Phone book server settings

Phonebook Server [1..5] ID: <S: 0, 64>

Enter a name for the external phonebook. Addresses the specific phonebook. Format: String with a maximum of 64 characters.

Example: Phonebook Server 1 ID: “”

Administrator Guide

About the settings

 

TheS ttingssettingsLibralibraryy

Cameras

Appendices

Contact us

 

 

 

 

 

 

Provisioning ExternalManager Protocol: <HTTP/HTTPS>

Determines whether or not to use secure management.

HTTP: Set to HTTP to disable secure management. Requires HTTP to be enabled in the Network Services HTTP Mode setting.

HTTPS: Set to HTTPS to enable secure management. Requires HTTPS to be enabled in the Network Services HTTPS Mode setting.

Example: Provisioning ExternalManager Protocol: http

Phonebook Server [1..5] URL: <S: 0, 255>

Enter the address (URL) to the external phonebook server. Addresses the specific phonebook server. Format: String with a maximum of 255 characters.

Example: Phonebook Server 1 URL: “http://tms.company.com/tms/public/external/ phonebook/phonebook.asmx”

The Provisioning settings

Provisioning Mode: <Off/TMS>

Provides the possibility of managing the codec (endpoint) by using an external manager/management system.

Off: The system will not try to register to any management system.

TMS: If set to TMS the system will try to register with a TMS server as described in Provisioning ExternalManager settings. TMS is short for TANDBERG Management System. Please contact your TANDBERG representative for more information.

Example: Provisioning Mode: TMS

Provisioning ExternalManager Address: <S: 0, 64>

If an External Manager address and a path is configured, the system will post an HTTP message to this address when starting up. When receiving this HTTP posting the External Manager (typically a management system) can return configurations/commands to the unit as a result. If the DHCP Option 242 is returned in the DHCP response from the DHCP server the system will interpret this as the External Manager address to use.

Specifies the IP Address to the External Manager/Management system. Format: String with a maximum of 64 characters.

Example: Provisioning ExternalManager Address: “”

Provisioning ExternalManager Path: <S: 0, 255>

If an External Manager address and a path is configured, the system will post an HTTP message to this address when starting up. When receiving this HTTP posting the External Manager (typically a management system) can return configurations/commands to the unit as a result. If the DHCP Option 242 is returned in the DHCP response from the DHCP server the system will interpret this as the External Manager address to use.

Specifies the path to the External Manager/Management system.

Example: tms/public/external/management/SystemManagementService.asmx

Format: String with a maximum of 255 characters.

Example: Provisioning ExternalManager Path: “”

The Serial port settings

SerialPort BaudRate: <9600/19200/38400/115200>

Specify the baud rate (bps) on the COM port (data port). The default value is 38400.

Other default parameters for the COM port are: Parity: None Databits: 8 Stopbits: 1 Flow control: None.

Valid inputs for baud rate: 9600, 19200, 38400, 115200

Example: SerialPort BaudRate: 38400

SerialPort LoginRequired: <On/Off>

The Serial Login setting determines whether or not there should be a login when connecting to the COM port (data port).

On: Login is required when connecting to the COM port (data port).

Off: The user can access the COM port (data port) without any login.

Example: SerialPort LoginRequired: Off

D14274.01—NOVEMBER 2008

29

Image 29
Contents November Tandberg T1What’s in this guide? Table of ContentsThis chapter IntroductionChapter Tandberg T1 at a glance Trademark Intellectual Property RightsDisclaimer Patent InformationWater and Moisture Safety InstructionsTANDBERG’s Environmental Policy Environmental IssuesGetting started System overview LAN Cable configurationsBatteries Using the Remote ControlCall KEY Using the Remote Control,If you need to set a static IP address Verify IP address settingsTurn on the system Add the system to the network Verify your settingsTime zone settings About the menus Administrator settings menu Settings The Settings menuAbout the menus Home The Home menuExplaining the administrator settings Settings menuIP Settings menu Administrator settingsSearch Advanced configuration menuSIP Administrator Settings LibraryAudio settings Advanced configuration menuAudio Output Line 1. Mode On/Off Audio Output Hdmi 1, 3 Mode On/OffAudio Input Line 1. Level Audio Input Line 1. Channel Left/Right/MonoCamera settings Conference settings Do not disturb setting Network settings Network services settings NetworkServices Snmp CommunityName S 0 NetworkServices Snmp Mode Off/ReadOnly/ReadWriteNetworkServices Snmp SystemContact S 0 NetworkServices Snmp SystemLocation S 0Serial port settings Phone book server settingsProvisioning settings Standby settings SIP Profile settingsTime zone setting System unit settingsVideo Input Source 2 Connector HDMI/HDSDI/YPbPr Video OSD Mode On/OffVideo Input Source 1. CameraControl Mode On/Off Video Input Source 1 Connector HDMI/HDSDI/YPbPrExample Video Output Hdmi 1 Resolution Video Output Composite 5 Resolution PAL/NTSCExample Video Output DVI 2 Resolution Example Video Output Composite 5 Resolution NtscCameras Hdmi and HD-SDI PrecisionHD 1080p cameraKensington lock Cascaded camerasTandberg T1 Connecting the cameraTandberg TRC5 Using Best viewBest view-Face recognition Line voltage frequency DIP switch settings for video output formatsVideo output formats Cameras in daisy chain Tandberg Dnam AppendicesPhysical conditions General room guidelinesRoom equipment Environmental considerationsNatural communication Audio qualityBest audio quality to all participants Making eye contactAdjust the camera view Guidelines for the telepresence room setupGeneral recommendations for the room layout Distance between the table and the video systemShows the PC presentation and the participants Sharing a PC presentationCamera view Guidelines for the high end meeting room setupAdministrator Guide Arrows Tandberg Remote Control TRC5Administrator settings Configure the video inputsAPI commands Video Input MatrixSoftware upgrade procedure Software upgradeUpload certificates Certificates upload procedureHow to upload the certificate Command ConfigurationXML files View XML filesDebug log files Log filesDnam Amplifier Dnam Loudspeaker CabinetNTP Time Zone expressions NTP Time Zone expressions, GMT0 GMT+0NZ-CHAT CETMedia capabilities supported in SIP Supported RFCs in SIPCurrent RFCs and drafts supported in SIP CE Declaration for Telepresence T1 China RoHS table Front view Tandberg T1 dimensionsLeft side view Top viewPrecisionHD 1080p camera dimensions PAL/NTSC Technical specificationsUnit Delivered Complete with HTTP, Https TCP/IP DhcpGpio Headquarters European Headquarters Tandberg