TANDBERG T1 manual Guidelines for the high end meeting room setup, Camera view

Page 45

T1

Contents

Introduction

Getting started

Guidelines for the high end meeting room setup

For high end team collaboration rooms, team meeting rooms and showroom floor.

General recommendations for the room layout

To fully utilize the telepresence experience there are some guidelines you should consider.

The distance between the table and the video system

The monitor is a 65” full HD LCD display and requires 2–2,5 m / 78–98 inch distance to the table to allow all participants to see a clear picture on screen

Make sure all participants are covered within the camera angle, which at maximum zoom out is 72°

Adjust the camera view (using zoom in/out) to allow the participants to be shown in full size on screen, and to keep eye contact with each other at the same eye level

The camera should capture all participants in the room

If the participants are sitting too close to the monitor the camera will “look down” at the participants. This may not give a good presentation of the participants at the far end.

The speaker module

The speaker module requires a minimum of 1,5 m / 59 inch free space in front

There should be free sight between the system speaker module and the ear of the participants.

The microphones

The microphones should be evenly distributed on the table

Avoid positions where they can be hidden behind obstacles like laptop or other equipment placed on the table

Do not place a microphone close to power outlets or similar arrangements on the table. The microphone may pick up noise from these arrangements quite strongly.

Administrator Guide

About the menus

About the settings

Settings Library

Cameras

 

AppenAppendicesi

Contact us

 

 

 

 

 

 

 

 

 

 

 

TANDBERG T1

 

 

 

 

Camera view

 

 

 

 

- with max zoom

Microphones

 

 

 

out

 

 

 

 

Remote

 

 

1.

 

 

4

2

 

7

 

5

 

0

8

6

3

control

 

 

9

 

 

 

#

 

 

 

 

 

Adjust the camera view

Press the Zoom +/– button on the remote control to adjust the picture on screen.

Adjust the camera view to allow the participants to have eye contact with each other at the same eye level.

D14274.01—NOVEMBER 2008

45

Image 45
Contents November Tandberg T1What’s in this guide? Table of ContentsIntroduction ChapterThis chapter Tandberg T1 at a glance Trademark Intellectual Property RightsDisclaimer Patent InformationWater and Moisture Safety InstructionsTANDBERG’s Environmental Policy Environmental IssuesGetting started System overview LAN Cable configurationsBatteries Using the Remote ControlCall KEY Using the Remote Control,Verify IP address settings Turn on the systemIf you need to set a static IP address Verify your settings Time zone settingsAdd the system to the network About the menus Administrator settings menu Settings The Settings menuAbout the menus Home The Home menuExplaining the administrator settings Settings menuIP Settings menu Administrator settingsSearch Advanced configuration menuSIP Administrator Settings LibraryAudio settings Advanced configuration menuAudio Output Line 1. Mode On/Off Audio Output Hdmi 1, 3 Mode On/OffAudio Input Line 1. Level Audio Input Line 1. Channel Left/Right/MonoCamera settings Conference settings Do not disturb setting Network settings Network services settings NetworkServices Snmp CommunityName S 0 NetworkServices Snmp Mode Off/ReadOnly/ReadWriteNetworkServices Snmp SystemContact S 0 NetworkServices Snmp SystemLocation S 0Phone book server settings Provisioning settingsSerial port settings Standby settings SIP Profile settingsTime zone setting System unit settingsVideo Input Source 2 Connector HDMI/HDSDI/YPbPr Video OSD Mode On/OffVideo Input Source 1. CameraControl Mode On/Off Video Input Source 1 Connector HDMI/HDSDI/YPbPrExample Video Output Hdmi 1 Resolution Video Output Composite 5 Resolution PAL/NTSCExample Video Output DVI 2 Resolution Example Video Output Composite 5 Resolution NtscCameras Hdmi and HD-SDI PrecisionHD 1080p cameraKensington lock Cascaded camerasTandberg T1 Connecting the cameraUsing Best view Best view-Face recognitionTandberg TRC5 DIP switch settings for video output formats Video output formatsLine voltage frequency Cameras in daisy chain Tandberg Dnam AppendicesPhysical conditions General room guidelinesRoom equipment Environmental considerationsNatural communication Audio qualityBest audio quality to all participants Making eye contactAdjust the camera view Guidelines for the telepresence room setupGeneral recommendations for the room layout Distance between the table and the video systemShows the PC presentation and the participants Sharing a PC presentationCamera view Guidelines for the high end meeting room setupAdministrator Guide Arrows Tandberg Remote Control TRC5Administrator settings Configure the video inputsAPI commands Video Input MatrixSoftware upgrade procedure Software upgradeCertificates upload procedure How to upload the certificateUpload certificates Command ConfigurationXML files View XML filesDebug log files Log filesDnam Amplifier Dnam Loudspeaker CabinetNTP Time Zone expressions NTP Time Zone expressions, GMT0 GMT+0NZ-CHAT CETSupported RFCs in SIP Current RFCs and drafts supported in SIPMedia capabilities supported in SIP CE Declaration for Telepresence T1 China RoHS table Front view Tandberg T1 dimensionsLeft side view Top viewPrecisionHD 1080p camera dimensions Technical specifications Unit Delivered Complete withPAL/NTSC TCP/IP Dhcp GpioHTTP, Https Headquarters European Headquarters Tandberg