Runco VX-40d, VX-50d, VX-80d, VX-60d manual Lens Replacement, Removing the Primary Lens

Page 88

Maintenance and Troubleshooting

5.2

Lens Replacement

If you need to remove the lens – either to replace it or to prepare the projector for shipment – proceed as follows:

1.Power down the projector and wait five minutes to allow the lamp to cool.

2.Remove the secondary anamorphic lens, if present.

3.Place the lens cap on the installed lens to protect it from damage.

4.Press and hold the “lens release” button located in the top right corner of the lens panel.

5.Grasping the lens barrel, turn it in a counter-clockwise direction until it stops. Then, pull it forward to remove it (disconnects from the connector assembly).

4

3

5

Note: The connector assembly moves as you turn the lens.

Figure 5-6. Removing the Primary Lens

76

Runco VX-40d/-50d/-60d/-80d Owner’s Operating Manual

Image 88
Contents VX-40d / VX-50d VX-60d / VX-80d Page TWO Year Limited Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Runco INTERNATIONAL, INC Safety Precautions Table of Contents Install Projector Stand CineWide with AutoScope, Floor-Mount Maintenance and Troubleshooting SpecificationsOperation Serial CommunicationsTable of Contents List of Figures Xii About This Manual Using This Manual Certain featuresSignificance. They also provide supplemental information Degrade performance or cause a malfunctionDescription, Features and Benefits Optional Accessories RuncoVX-40d/-50d/-60d/ -80d at a Glance VX-40d/-50d/-60d/-80d Top/Rear/Front ViewRear Foot Stationary Power Input 100 to 240 VAC VX-40d/-50d/-60d/ -80d Input PanelRS232 RS232 OUT Not used RS422 Not used Gpio Not usedInput 3 Video / Input 4 S-Video Input 2 DVIVX-40d/-50d/-60d/ -80d Rear-Panel Keypad FocusZoom VX-40d/-50d/-60d/-80d has its own internal menu systemMenu Navigation Buttons Input 1 BNCHelp ExitDHD Controller Front Panel DHD Controller Front PanelDHD Controller Rear Panel OutputsHD1 / HD2 Analog BNC connectors Component Video RCA connectorsInputs 3. DVI 1 / DVI 2 Digital Video 1 / S-VIDEORemote Control DHD ControllerOn / OFF Cursor ButtonsFor more information about aspect ratios, refer to Table VideoMemory Preset Buttons ISF NT Night Aspect Ratio Selection ButtonsANA Anamorphic 4X3 Standard 43Controls and Functions Installation Quick Setup Installation OverviewInstallation specialist Step Procedure For Details, Refer toInstallation Considerations Projector Installation OptionsInstallation Type Ambient LightVX-40d/-50d Lens Options and Throw Ratios Throw Ratio Throw Distance RangeLens Option Note Throw Dist Minimum MaximumVX-60d/-80d Lens Options and Throw Ratios Lens Option Note Throw Dist Screen Width Minimum MaximumVertical and Horizontal PositionHorizontal Lens Shift Screen center are aligned with each otherFolded Optics Installing the Projection Lens Lens Assembly Front ViewAutoScope or Base Plate Installing the Optional CineWide Lens MountFixed CineWide Are both fully assembled AutoScope stand used for floor-mounted projector Adjusting the Projection Mounting VX-40d/-50d/-60d/ -80dFloor Mounting Ceiling MountingConnector Panel Access Connecting the DHD Controller to VX-40d/-50d/-60d/-80dConnecting Source Digital DTV RGB or Component Video Connections See Figure 10. Digital DTV RGB or Component Video ConnectionsAnalog Computer RGB Connections See Figure 11. Analog RGB ConnectionsComposite/S-Video/Component Video Connections See Figure 12. Composite, S-Video and Component Video ConnectionsConnecting 12-Volt RS-232 ControllerConnection Trigger Outputs toConnecting to AC Power Input voltage to the AutoScope lens motor must be betweenYou must enter a passcode to access the Service menu Turning on the PowerSelecting the Input Source Adjusting the Picture Orientation Primary Lens Adjustments Focus Zoom Vertical and Horizontal Lens ShiftInstalling and Adjusting the CineWide Anamorphic Lens Assembly to Lens MotorCarriage Plate CineWide With AutoScope or BaseHorizontal Position X Adjustment Too Low Correct position Too High Wrong Position Correct Position GeometryCalibrating Projector Inputs Main TheaterMaster Remote 1. Power Button Control Functions Channel Setup Are disabledNavigating the Projector Menus 17. Copying a Channel Auto Setup You cannot use Auto Setup with a locked channel. Copy18. Resize Presets No Resizing Native aspect ratio is with the primary lens only. With anInstallation Values shown represent where the approximate center Adjust Pixel Tracking before Pixel PhaseRecommended see below Experienced technicians use the Input Levels submenu Input Levels are not applicable to DVI InputOn an internal grayscale test pattern There must be at least two consecutive white pixels present Uncheck this item before exiting this menuWorking With the Lamp Originally expected may no longer be possibleIntensity value is not the actual lumen output, but rather a More easily maintained as the lamp ages Installation Using the On-Screen Menus OperationISF Presets ServiceInput Source Aspect RatioMain Menu Input SourceAspect Ratio HD Pass Thru 1 HD Pass ThruAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position ResolutionInput Position Left/Right Up/Down Width Height Overscan ISF Presets ISF Presets ISF Night ISF Day Custom Save Factory DefaultInformation Serial Number Hardware Firmware 0002.003A Date Mar 15You must enter a passcode to access the Calibration menu CalibrationOperation Service Input Names Restore Composite Video Component SDTip HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV ADC Bandwidth Auto YPbPr Input ResolutionAuto Operation Lamp and Filter Replacement Removing the Lamp DoorRemoving the Lamp Recording the Serial Number of a New Lamp Lamp is accurateLens Replacement Removing the Primary LensTroubleshooting Chart Troubleshooting TipsSymptom Possible Causes Solution Power down the projector Error Codes VX-40d/-50d/-60d/-80d Error CodesCode Description General Power and Cooling Code Description Lamp FailuresBuilt-In Keypad Code Description Tipm Image ProcessorPanel Driver and Formatter Code Description Miscellaneous RS-232 Connection and Port Configuration Serial Command SyntaxSerial Commands CommandAspect Ratio Commands VIRTUAL235 YESImage Preset Commands Value Description Min/max Stored? Input Position Commands Output Shift CommandsBkgnd Serial Communications VX-40d/-50d/-60d/ -80d Specifications VX-40d/-50d/-60d/-80d SpecificationsHome Theater Calibration Specifications Industry-Standard SpecificationsPower Requirements VX-40d/-60d VX-50d/-80dDimensions Weight without lensLimited Warranty Specifications are subject to change without noticeDHD Controller Specifications DHD Controller SpecificationsVX-40d/-50d/-60d/ -80d Dimensions VX-40d/-50d/-60d/-80d DimensionsSpecifications Page Runco CL-810 Owner’s Operating Manual