American Power Conversion Bypass Static manual Output Summary Screens, Normal Output Summary

Page 13

Output Summary Screens

The three Output Summary screens provide output-specific status of voltage, power, current, frequency, etc.

UPS Summary

~ ~

Q7

 

Q8

 

 

 

Normal

0:00 AM

Q2

Normal

Normal

Output Summary

5.40 PM

The black bars represent real-time data. Yellow triangles represent the maximum values recorded to date and blue triangles represent the minimum values recorded to date.

 

Current

 

 

 

A

 

587

 

 

 

522

 

 

 

456

 

 

 

391

 

 

 

326

 

 

 

262

 

 

 

196

 

 

 

130

 

 

 

65

 

 

 

0

13

13

13

 

 

 

 

L1

L2

L3

 

Voltage

 

 

 

V

 

607

 

 

 

540

 

 

 

472

 

 

 

405

 

 

 

337

 

 

 

270

 

 

 

202

 

 

 

135

 

 

 

67

 

 

 

0

259

264

263

 

 

 

 

L1-2 L2-3 L3-1

495

440

365

330

275

220

165

110

55

0

Total Power

kW kVA

450 453

 

Frequency

 

Hz

55.0

 

54.0

 

53.0

 

52.0

 

51.0

 

50.0

 

49.0

 

48.0

 

47.0

 

46.0

 

45.0

259

 

Page 1 of 3

These values will be reset when the output statistics are reset

Normal

 

 

Normal

 

 

Normal

 

 

Output Summary

Output Summary

5.400:00PMAM

Refresh Data

Voltage

Current

Normal

Normal

5.40 PM

 

 

L1

L2

L3

 

 

 

L1

L2

L3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current

57.0

59.0

62.0

A

 

Active power

380

381

382

kW

 

 

200.0

 

 

 

Current high

60.0

63.0

66.0

A

Active power high

700

701

702

kW

 

 

 

Peak current

20.0

19.5

20.0

A

Apparent power

700

692

694

kVA

 

 

 

 

 

 

Peak current high

59.4

59.9

60.4

A

Apparent power high

690

682

684

kVA

 

 

 

 

THD

3.9

4.8

5.8

%

 

Power factor

0.92

0.81

0.82

 

 

 

 

 

 

 

THD high

3.8

4.7

5.7

%

 

Total active power

 

 

200

kW

 

 

 

 

 

Crest factor

2.1

2.13

2.23

 

 

Total apparent power

 

 

150

kVA

 

 

 

 

Crest factor high

2.03

2.06

2.16

 

 

 

 

 

 

 

 

 

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1-2

L2-3

L3-1

 

 

Frequency

 

 

51.4

Hz

 

 

 

 

 

 

 

 

Frequency high

 

 

54.2

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

220.5

221.0

222.0

V

 

Frequency low

 

 

45.8

Hz

 

 

 

 

Voltage high

260.0

261.0

262.0

V

Tolerance

 

 

2.0

%

 

 

 

 

 

 

Voltage low

200.0

201.0

202.0

V

 

 

 

 

 

 

 

-200.0

 

 

 

THD

 

 

4.8 %

 

Load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THD high

2.7

3.6

4.6 %

 

 

 

 

 

 

 

 

 

 

 

 

Load

60.0

68.0

78.0

%

 

 

 

 

 

 

Voltage tolerance

 

 

5 %

 

 

 

0.0

5.0

10.0

15.0

 

 

 

Load high

58.0

66.0

76.0

%

 

 

Waveform tolerance

 

 

6 %

 

 

 

Tolerance conditions

 

 

29

 

 

Total load

 

 

142.0

%

 

 

 

 

Time (ms)

 

 

 

 

 

Total load high

 

 

250.0

%

Page 2 of 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 3 of 3

Symmetra® MW with Internal Bypass Static Switch - User Guide - 990-1756A-001

7

Image 13
Contents Symmetra MW UPS Page Contents Operation Modes Alarms/Troubleshooting Page Symbols used in this guide SafetyUser Safety Navigation symbols Display Symbols and ButtonsScreen symbols UPS DisplayEMO ButtonsUPS Summary UPS Summary Screen~ ~ Input Summary ScreensNormal Output Summary Output Summary Screens~ ~ Bypass Summary ScreensCurve shows the battery Battery Summary ScreensOperation Operation ScreenUPS Startup UPS Start-Up ScreenUPS Shutdown UPS Shutdown screenOnline to Static Bypass Online to Static Bypass ScreenStatic Bypass to Online Screen Network Settings screen Network Configuration ScreensNetwork Settings Mail Settings Mail Settings screenSnmp Settings Snmp Settings screenRemote Monitoring Service Settings Remote Monitoring Service Settings screenAPC ISX Manager Settings APC ISX Manager Settings screenTouch-Screen Settings screen User Configuration ScreensModbus Settings screen Password Settings screenBattery Test screen Regional Settings screenUPS Display User Configuration Screens Event Log Screen AlarmSevereNormal EventLogLogInverter DC Capacitors screen Predictive Maintenance ScreensInverter DC Capacitors Inverter AC Capacitors Inverter AC Capacitors screenTop Fans Top Fans screenInverter Fans Inverter Fans screenMain Static Switch Fans Main Static Switch Fans screenPage On-line Operation Operation ModesBattery Operation Bypass Operation Manual Bypass Operation System Start-Up from Manual Bypass Operation Select Operation Configuration Select Start-upOperation Modes System Start-Up from Manual Bypass Operation System Shutdown from Online to Manual Bypass Operation Select Operation ConfigurationPage Online to Static Bypass Transfer from Online to Static Bypass OperationSelect Static Bypass Online on Operation screen Transfer from Static Bypass to Online OperationAlarm Types Alarms/TroubleshootingInfo SevereActive Alarms View active alarmsAPC Symmetra MW Remote Display Starting web-based remote session Factory Warranty WarrantyLife Support Policy Air Filter Exchange Appendix aAppendix a Air Filter Exchange Page APC Worldwide Customer Support