American Power Conversion Bypass Static manual Bypass Summary Screens, ~ ~

Page 14

Bypass Summary Screens

The two Bypass Summary screens provide status of voltage, power, current, frequency, etc.

Bypass Summary

~ ~

Q7

 

Q8

 

 

 

Normal

0:00 AM

Q2

Normal

Normal

Bypass Summary

5.40 PM

The black bars represent real-time data. Yellow triangles represent the maximum values recorded to date and blue triangles represent the minimum values recorded to date. These values will be reset when the bypass statistics are reset

 

Current

 

 

 

A

 

110

 

 

 

88

 

 

 

86

 

 

 

73

 

 

 

61

 

 

 

49

 

 

 

37

 

 

 

24

 

 

 

12

 

 

 

0

59

61

63

 

 

 

 

L1

L2

L3

 

Voltage

 

 

 

V

 

336

 

 

 

236

 

 

 

207

 

 

 

177

 

 

 

140

 

 

 

110

 

 

 

90

 

 

 

59

 

 

 

30

 

 

 

0

200

203

205

 

 

 

 

L1-2 L2-3 L3-1

127

112

108

84

70

56

42

20

14

0

Total Power

kW kVA

83 118

80.0

57.8

55.6

53.3

51.0

40.9

46.7

44.4

42.2

40.0

Frequency

Hz

51,8

Page 1 of 2

BypassOutputSummary

Ready

Normal

Normal

2.07 PM

0:00 AM

Current

200.0

200.0

200.0

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current high

500.0

500.0

500.0

A

 

 

 

 

 

 

 

Peak Current

200.0

200.0

200.0

A

 

 

 

 

 

 

 

Peak Current high

300.0

300.0

300.0

A

 

 

 

 

 

 

 

Crest factor

0.0

0.0

0.0

 

 

 

 

 

 

 

 

Crest factor high

0.0

0.0

0.0

 

 

Power factor

0.5

0.5

0.5

 

 

 

Active power

100

100

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Active power high

200

200

200

kW

 

 

 

 

 

 

 

Apparent power

200

200

200

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

Apparent power high

200

200

200

kW

Voltage

xxx.0

xxx.0

xxx.0

V

 

 

Total active power

 

 

 

200

kW

Voltage high

490.0

490.0

490.0

V

 

 

 

 

 

Total active power high

 

 

 

200

kW

Voltage low

470.0

470.0

470.0

V

 

Total apparent power

 

 

 

200

kW

THD

5.0

5.0

5.0 %

 

Total apparent power high

 

 

 

0

kW

Load

L1

L2

L3

 

 

 

 

 

 

 

 

Load

10.0

10.0

10.0 %

 

 

 

 

 

 

 

 

Frequency

 

 

 

60.0

Hz

Load high

99.0

99.0

99.0

%

 

Frequency high

 

 

 

61.0

Hz

Total load

 

 

0.0

%

 

Frequency low

 

 

 

59.0

Hz

Total load high

 

 

0.0

%

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

Mains SSW

 

 

 

68

¡ F

 

 

 

 

 

 

 

Mains SSW High

 

 

 

68

¡ F

Page 2 of 2

8

Symmetra® MW with Internal Bypass Static Switch - User Guide - 990-1756A-001

Image 14
Contents Symmetra MW UPS Page Contents Operation Modes Alarms/Troubleshooting Page Safety Symbols used in this guideUser Safety Screen symbols Display Symbols and ButtonsNavigation symbols UPS DisplayButtons EMOUPS Summary Screen UPS SummaryInput Summary Screens ~ ~Output Summary Screens Normal Output SummaryBypass Summary Screens ~ ~Battery Summary Screens Curve shows the batteryOperation Screen OperationUPS Start-Up Screen UPS StartupUPS Shutdown screen UPS ShutdownOnline to Static Bypass Screen Online to Static BypassStatic Bypass to Online Screen Network Settings Network Configuration ScreensNetwork Settings screen Mail Settings screen Mail SettingsSnmp Settings screen Snmp SettingsRemote Monitoring Service Settings screen Remote Monitoring Service SettingsAPC ISX Manager Settings screen APC ISX Manager SettingsUser Configuration Screens Touch-Screen Settings screenPassword Settings screen Modbus Settings screenRegional Settings screen Battery Test screenUPS Display User Configuration Screens AlarmSevereNormal EventLogLog Event Log ScreenInverter DC Capacitors Predictive Maintenance ScreensInverter DC Capacitors screen Inverter AC Capacitors screen Inverter AC CapacitorsTop Fans screen Top FansInverter Fans screen Inverter FansMain Static Switch Fans screen Main Static Switch FansPage Operation Modes On-line OperationBattery Operation Bypass Operation Manual Bypass Operation Select Operation Configuration Select Start-up System Start-Up from Manual Bypass OperationOperation Modes System Start-Up from Manual Bypass Operation Select Operation Configuration System Shutdown from Online to Manual Bypass OperationPage Transfer from Online to Static Bypass Operation Online to Static BypassTransfer from Static Bypass to Online Operation Select Static Bypass Online on Operation screenInfo Alarms/TroubleshootingAlarm Types SevereView active alarms Active AlarmsAPC Symmetra MW Remote Display Starting web-based remote session Warranty Factory WarrantyLife Support Policy Appendix a Air Filter ExchangeAppendix a Air Filter Exchange Page APC Worldwide Customer Support